Science · Biometrics

Biometrics

Every metric Sensor Bio reports, from heart rate and HRV to SpO2 and sleep, with its unit, the signal it comes from and where it is computed.

Heart rate

Heart rate on Sensor Bio V2 is beats per minute measured from the wrist PPG pulse and computed on the device. In the standard export, readings arrive about every 5 minutes while awake and every 2 minutes during sleep and workouts. Resting heart rate is the lowest sustained heart rate during sleep, computed in the cloud from overnight data, and each night also reports sleep average, minimum and maximum heart rate.

Related PPG beat detection algorithmsPPG signal quality

Unit
bpm
Derived from
Beat-to-beat intervals in the PPG signal
Computed
On device. Resting heart rate in the cloud.
Captured
About every 5 min awake, 2 min in sleep and workouts

Heart rate variability (HRV)

Sensor Bio reports heart rate variability as rMSSD in milliseconds, the root mean square of successive differences between beats. HRV is computed on the device from beat-to-beat intervals when the signal is clean and the wearer is still, and it needs PPG sampling of at least 50 Hz, the V2 default. Each night adds resting HRV from the lowest-activity period of sleep, plus sleep average, minimum and maximum HRV, and spot checks add SDNN.

Related How researchers use continuous HRV

Unit
ms (rMSSD; SDNN in spot checks)
Derived from
Beat-to-beat intervals
Computed
On device. Resting HRV in the cloud.
Captured
Every 2 min overnight, during the day when the signal allows

Blood oxygen (SpO2)

SpO2 on Sensor Bio V2 is a wellness trend of blood oxygen saturation, estimated from the red and infrared PPG channels together. It needs both red and infrared enabled in the sensor configuration, and it is reported as a percentage for general wellness use, not as a medical oximeter reading.

Related Nocturnal SpO2: measurement limits

Unit
% saturation
Derived from
Red and infrared PPG
Requires
Red and infrared channels both enabled
Use
General wellness trend

Respiratory rate

Respiratory rate on Sensor Bio V2 is breaths per minute, derived from the rhythmic change in beat-to-beat intervals that comes with each breath. It is computed on the device, day or night, whenever enough clean beat-to-beat intervals are available, and like HRV it needs PPG sampling of at least 50 Hz. Spot checks also report it for the reading window.

Related How PPG works

Unit
Breaths per minute
Derived from
Respiratory sinus arrhythmia in beat-to-beat intervals
Computed
On device
Captured
Day or night when enough intervals are valid

Skin temperature

Skin temperature on Sensor Bio V2 is continuous wrist surface temperature, read against each wearer's own baseline. A dedicated sensor on the underside of the band takes a reading once a minute by default, and the platform reports minimum, maximum, average and deviation from baseline. It tracks change in skin temperature, not core body temperature.

Related Wrist skin temperature and sleep onset

Unit
°C or °F
Derived from
Dedicated skin temperature sensor
Reported as
Min, max, average, deviation from baseline
Captured
Once a minute by default

Sleep

Sensor Bio detects sleep automatically and classifies each minute as awake, light, deep or REM from heart rate, HRV, respiratory rate and movement. Staging runs in the mobile app, and each night reports sleep start, onset, wake-up and end times, minutes in each stage, sleep efficiency, sleep latency, time in bed and arousal count. Full REM staging needs enough PPG sampling; otherwise the system uses three stages: light, deep and wake.

Related Meditation and sleep architecture

Unit
Minutes per stage, timestamped stage transitions
Derived from
Heart rate, HRV, respiratory rate, accelerometer
Computed
Mobile app. Sleep score in the cloud.
Captured
Every 2 min during detected sleep

Recovery, activity and sleep scores

Recovery, sleep and activity scores are 0 to 100 composites computed in the cloud from the same biometrics listed above. The recovery score is an overnight readiness composite that appears after a 5-night baseline, the sleep score combines sleep quality and duration, and the activity score combines heart rate reserve with movement across the day. Steps, distance, active calories and active seconds come from the accelerometer, so every score can be traced back to the data underneath it.

Related REST API

Unit
Score 0 to 100. Steps, meters, kcal, seconds.
Derived from
Overnight and daytime biometrics, accelerometer
Computed
Cloud. Steps on device.
Baseline
Recovery appears after 5 nights

Spot checks and live stream

A spot check is a guided reading of at least 3 minutes, started from the app while the wearer holds still. It reports heart rate, rMSSD, SDNN, mean RR interval, respiratory rate, a stress index, frequency-domain HRV (LF, HF and the LF/HF ratio), Poincaré SD1 and SD2, parasympathetic and sympathetic scores, and signal-to-noise ratio in dB. During an active recording, the Mobile SDK live stream carries heart rate, HRV, respiratory rate, beat-to-beat intervals, raw PPG and motion.

Related Mobile SDK

Length
At least 3 minutes, wearer still
Derived from
Beat-to-beat intervals from a dedicated sensing window
Computed
Mobile app
Quality
Signal-to-noise ratio (dB) on every reading

This page describes what Sensor Bio measures, not what a value means for an individual. For general reference ranges and their sources, see these biometric reference charts.

Raw signals and derived metrics

Every Sensor Bio metric is derived from three raw signals: multi-wavelength PPG, a 3-axis accelerometer and skin temperature. Raw waveforms are available through the Mobile SDK raw stream and a per-organization web platform download. Computed metrics are available through the REST API, the SDK and CSV or JSON export.

DataTypeComes fromComputed in
PPG waveform (green, red, infrared)RawOptical sensorUnfiltered
Accelerometer (x, y, z)Raw3-axis accelerometerUnfiltered
Skin temperatureRawSkin temperature sensorOn device
Beat-to-beat intervalsDerivedPPGOn device
Heart rate, HRV, respiratory rateDerivedBeat-to-beat intervalsOn device
Steps and cadenceDerivedAccelerometerOn device
SpO2DerivedRed and infrared PPGSensor Bio platform
Sleep stages, spot checksDerivedHR, HRV, respiratory rate, motionMobile app
Resting HR, resting HRV, scoresDerivedOvernight and daily biometricsCloud

Sensor specifications for Sensor Bio V2Raw data accessRaw PPG access for partners

Biometric data in the API and SDK

Each Sensor Bio metric maps to a REST API field and a Mobile SDK method with the same name on iOS and Android. Field and method names below come from the public developer docs.

  • Heart rate

    REST API

    GET /v1/biometrics bpm, resting_bpm

    Mobile SDK

    fetchDailyHR, getHRPoints

  • HRV (rMSSD)

    REST API

    GET /v1/biometrics hrv, resting_hrv

    Mobile SDK

    fetchDailyHRV, getHRVPoints

  • SpO2

    REST API

    GET /v1/biometrics spo2

    Mobile SDK

    fetchDailySpO2

  • Respiratory rate

    REST API

    GET /v1/biometrics brpm

    Mobile SDK

    fetchDailyRR, getRRPoints

  • Skin temperature

    REST API

    Not listed in the API reference

    Mobile SDK

    getSkinTemperature

  • Sleep

    REST API

    GET /v1/sleep light_sleep_mins, deep_sleep_mins, rem_sleep_mins, score

    GET /v1/sleep/details/day sleep_stages

    Mobile SDK

    getSleepDetail, getSleepSessions

  • Recovery and activity

    REST API

    GET /v1/scores recovery, activity, sleep

    GET /v1/scores/recovery/details score

    GET /v1/steps steps

    Mobile SDK

    fetchDailyRecovery, fetchDailyActivityDetail

  • Spot checks

    REST API

    Not listed in the API reference

    Mobile SDK

    fetchSpotCheckDetails

REST API referenceiOS SDK referenceAndroid SDK reference

Questions

FAQ

What biometrics does Sensor Bio V2 measure?

Sensor Bio V2 reports heart rate, resting heart rate, HRV as rMSSD, SpO2, respiratory rate, skin temperature, sleep stages, steps and activity, plus recovery, sleep and activity scores. All of them are derived from raw PPG, accelerometer and skin temperature data that teams can also access directly.

Which HRV measure does Sensor Bio report?

Sensor Bio reports HRV as rMSSD in milliseconds, continuously and as a nightly resting value. Spot checks add SDNN, frequency-domain LF and HF power, and Poincaré SD1 and SD2.

How often does Sensor Bio V2 capture biometrics?

Sensor Bio V2 captures biometric readings about every 5 minutes while the wearer is awake and every 2 minutes during sleep and workouts. Duty cycle and sampling rate are configurable per organization.

Does Sensor Bio V2 measure SpO2?

Yes. Sensor Bio V2 estimates SpO2 from its red and infrared PPG channels and reports it as a general wellness trend. It is not a medical oximeter.

Is skin temperature the same as body temperature?

No. Sensor Bio V2 measures wrist skin temperature and reports change against each wearer's own baseline. It does not measure core body temperature.

Can I get the raw data behind each metric?

Yes. Raw multi-wavelength PPG and 3-axis accelerometer data are available through the Mobile SDK raw stream and a per-organization web platform download, alongside computed metrics through the REST API and CSV or JSON export.

Is Sensor Bio V2 a medical device?

No. Sensor Bio V2 is a general wellness device. It is not FDA cleared and is not intended to diagnose, treat, cure or prevent any disease.

Algorithm store

Add more with the Algorithm Store

Add-on algorithms run on the same raw signal as the core biometrics. Availability and integration details are shared on request.

Sensor Bio V2 is a general wellness device. It is not FDA cleared and is not intended to diagnose, treat, cure or prevent any disease. Biometrics on this page are wellness trends for general wellness, research and product development use.