For research programs and algorithm partners

Wearable sensor configuration, set per state.

Wearable sensor configuration is the set of rules that decides what a device captures, when it captures, and at what fidelity. On Sensor Bio V2, each parameter is set independently per sensor state, per device and per organization: PPG sampling rate (25, 50 or 100 Hz), green, red and infrared wavelengths, duty cycle, accelerometer, skin temperature and sleep triggers.

Download the configuration sheet (PDF)partners@sensorbio.com

01Configure your study

Pick a state, set the dials, and see what the signal unlocks. This is how configurable a research wearable can be: every dial below is set per state, per device and per organization.

PPG sampling ratedefault
PPG wavelengths
Accelerometer logging

Logs during the windows your configuration sets, with or without PPG captures.

Skin temperature (°C)
Triggersstart and end, local time
Time-window trigger
Rest-mode trigger (low motion)
What the signal unlocksTriggered state, 50 Hz
Heart rateavailableHRVavailableBreathing rate (RR)availablePPG morphologynot available at this settingSpO2availableMovement contextavailableSkin temperature trendavailableSleep-stage research signalavailable
A day on the deviceexample day, local time, capture windows not to scale
00:0003:0006:0009:0012:0015:0018:0021:0000:00PASSIVETRIGGEREDACTIVErestsession

Passive 14 h 30 mTriggered 8 h 45 mActive 0 h 45 mPPG capture 7 h 18 m

Passive 14 h 30 m · Triggered 8 h 45 m · Active 0 h 45 m · PPG capture 7 h 18 m

Streams that shipCSV per stream, UTC timestamps

PPGppg.csv

ts,green,ir,red
1793257200000000000,…,…,…

IMUaccelerometer.csv

ts,x,y,z
1793257200000,…,…,…

Tempskin_temp.csv

ts,skin_temp_c
1793257200000000000,…

IMU means the 3-axis accelerometer. PPG ts is in nanoseconds and green, ir and red are raw amplitudes in AU. Accelerometer ts is in milliseconds and x, y, z are in m/s². The skin temperature column is an example.

Illustrative only. Sensor Bio sets and applies the final configuration for your organization's devices. Example capture windows are not to scale.

02Sensor states

One device. Three operating modes, configured independently.

StateActivationBehavior
PassiveDefault, idleThe device baseline. Governs all background sensor logging.
TriggeredTime window or restTurns on during a set clock window or when the wearer is at rest (low motion). Tuned for the sleep-stage signal.
ActiveUser sessionA workout or session started in the Sensor Bio app. The highest throughput in the system.

03Configurable parameters

Every dial that matters, set per state, per device and per organization.

ParameterAvailable settings
PPG duty cycleOn-time and interval, or continuous. Default: 50 Hz for 45 seconds every 5 minutes
PPG sampling rate25, 50 or 100 Hz
Accelerometer loggingOn or off, gated or continuous (3-axis accelerometer, ±8 g by default, up to ±16 g), with or without PPG captures
Skin temperatureOn or off, skin-surface °C, 1 reading per minute by default
Time-window triggerStart and end clock times
Rest-mode triggerOn or off, low-motion activation

Duty cycle is the trade at the center of every study. By default, V2 captures PPG at 50 Hz for 45 seconds every 5 minutes. A longer on-time or a shorter interval gives you more signal, and more data to store and sync. Set it per state, so a sleep window can run dense while the rest of the day stays light.

04Sampling rates

What the model sees.

RateWhat it unlocks
25 HzHeart rate only. HRV and breathing rate (RR) degrade.
50 HzDefaultHeart rate, HRV, breathing rate (RR)
100 HzHeart rate, HRV, breathing rate (RR), PPG morphology

Need the pulse shape itself? 100 Hz keeps the waveform detail used for morphology work.

05PPG wavelengths

Three wavelengths, switched on per state.

WavelengthPrimary use
Green530 nm. Heart rate and HRV. Best at rest.
Red655 nm. SpO2, paired with infrared.
Infrared940 nm. SpO2. Standard in sleep mode.

How green, red and infrared light read the pulse is covered on the science page.

06Who it is for

Partners who measure their own ground truth.

PartnerFocus
Algorithm developersModels that need a fixed signal contract.
Sleep researchFour-stage sleep (wake, light, deep, REM) research signal at a high duty cycle.
Clinical and academic researchProtocol-defined sensing windows.
Remote monitoring programsBattery life, sync and signal density at fleet scale.

One research wearable, configured four ways. A sleep study wearable runs dense through a nightly window. An algorithm team locks one signal contract across every device. A remote monitoring program keeps passive logging light so the fleet stays charged and in sync.

07What ships

Raw physiological signal in your format. White-glove configuration.

StreamsTimestampsDeliveryConfiguration
PPG, accelerometer, skin temperatureUTC epoch. Nanoseconds for PPG, milliseconds for accelerometerOne CSV per streamSet by Sensor Bio

Raw files come through your organization's download from the Sensor Bio web platform, and live raw PPG is available through the mobile SDK. See raw data for file details.

ppg.csv

ts,green,ir,red
ts
UTC epoch timestamp, nanoseconds
green
Raw green amplitude, AU, unfiltered. Default channel
ir
Raw infrared amplitude, AU, unfiltered. When enabled
red
Raw red amplitude, AU, unfiltered. When enabled

accelerometer.csv

ts,x,y,z
ts
UTC epoch timestamp, milliseconds
x, y, z
Unfiltered axis values, m/s²

skin_temp.csvExample

ts,skin_temp_c
ts
UTC epoch timestamp. Example
skin_temp_c
Skin-surface temperature, °C. Example column name

PPG and accelerometer fields match the V2 raw export. File names and the skin temperature columns are examples. Columns follow the wavelengths and streams you turn on.

08How configuration works

You define it. We apply it. The signal ships.

01 You define

What each device captures, when it captures, and at what fidelity, state by state.

02 We apply

Sensor Bio configures your sensors white-glove, based on how your team needs them set up, for your organization and, where your protocol needs it, for individual devices.

03 Signal ships

Raw PPG, accelerometer and skin temperature, one CSV per stream, with UTC timestamps.

FAQ

Questions, answered.

What can I configure on Sensor Bio V2?

Six parameters, each set per sensor state, per device and per organization: PPG duty cycle, PPG sampling rate (25, 50 or 100 Hz), accelerometer logging, skin temperature, a time-window trigger and a rest-mode trigger. You also choose which PPG wavelengths run: green, red and infrared. That level of control is what makes V2 a configurable research wearable rather than a fixed consumer tracker.

Which PPG sampling rate should I choose?

50 Hz is the default and covers heart rate, HRV and breathing rate (RR), reported in breaths per minute as resp_rate_brpm in the API. 25 Hz keeps heart rate but HRV and breathing rate degrade, so it suits light background logging. 100 Hz adds PPG morphology, the pulse shape itself, for teams building waveform models. Higher rates produce more data to store and sync.

What are the three sensor states?

Passive is the default baseline that governs background logging. Triggered turns on during a clock window or when the wearer is at rest, and it is tuned for the sleep-stage signal. Active runs during a workout or session started in the Sensor Bio app and has the highest throughput. Each state has its own configuration.

How do I set up a sleep study wearable configuration?

Use the Triggered state. Set a time-window trigger for the nightly sleep period, turn on the rest-mode trigger for low-motion periods, and run a high duty cycle with green and infrared PPG plus the accelerometer. Passive logging can stay light during the day. Sensor Bio applies the final configuration for your protocol.

Can different devices in one study run different configurations?

Yes. Configuration is set per organization and per device, so a study arm or cohort can run a different sampling rate, duty cycle or trigger window. Sensor Bio sets and applies these configurations for you.

What format does the raw data ship in?

One CSV per stream: PPG, accelerometer and skin temperature, each with UTC epoch timestamps. PPG files carry ts, green, ir and red, with raw amplitudes in arbitrary units and nanosecond timestamps. Accelerometer files carry ts, x, y and z, in m/s² with millisecond timestamps. Files come through your organization's download from the web platform, and live raw PPG is available through the mobile SDK.

Is Sensor Bio V2 a medical device?

No. Sensor Bio V2 is a general wellness device. It is not FDA cleared and is not intended to diagnose, treat, cure or prevent any disease. Configured data is for wellness, research and product development use.

Related

Protect the Signal.

Configure Sensor Bio V2 for your study.

Tell us your protocol. We set the configuration and ship the raw signal.

Sensor Bio V2 is a general wellness device. It is not FDA cleared and is not intended to diagnose, treat, cure or prevent any disease. Configuration options are set by Sensor Bio per organization. The study builder on this page is illustrative.

Download the configuration sheet (PDF)