For research programs and algorithm partners
Wearable sensor configuration, set per state.
Wearable sensor configuration is the set of rules that decides what a device captures, when it captures, and at what fidelity. On Sensor Bio V2, each parameter is set independently per sensor state, per device and per organization: PPG sampling rate (25, 50 or 100 Hz), green, red and infrared wavelengths, duty cycle, accelerometer, skin temperature and sleep triggers.
Download the configuration sheet (PDF)partners@sensorbio.com
01Configure your study
Pick a state, set the dials, and see what the signal unlocks. This is how configurable a research wearable can be: every dial below is set per state, per device and per organization.
Logs during the windows your configuration sets, with or without PPG captures.
Passive 14 h 30 mTriggered 8 h 45 mActive 0 h 45 mPPG capture 7 h 18 m
Passive 14 h 30 m · Triggered 8 h 45 m · Active 0 h 45 m · PPG capture 7 h 18 m
PPGppg.csv
ts,green,ir,red
1793257200000000000,…,…,…IMUaccelerometer.csv
ts,x,y,z
1793257200000,…,…,…Tempskin_temp.csv
ts,skin_temp_c
1793257200000000000,…IMU means the 3-axis accelerometer. PPG ts is in nanoseconds and green, ir and red are raw amplitudes in AU. Accelerometer ts is in milliseconds and x, y, z are in m/s². The skin temperature column is an example.
Illustrative only. Sensor Bio sets and applies the final configuration for your organization's devices. Example capture windows are not to scale.
02Sensor states
One device. Three operating modes, configured independently.
| State | Activation | Behavior |
|---|---|---|
| Passive | Default, idle | The device baseline. Governs all background sensor logging. |
| Triggered | Time window or rest | Turns on during a set clock window or when the wearer is at rest (low motion). Tuned for the sleep-stage signal. |
| Active | User session | A workout or session started in the Sensor Bio app. The highest throughput in the system. |
03Configurable parameters
Every dial that matters, set per state, per device and per organization.
| Parameter | Available settings |
|---|---|
| PPG duty cycle | On-time and interval, or continuous. Default: 50 Hz for 45 seconds every 5 minutes |
| PPG sampling rate | 25, 50 or 100 Hz |
| Accelerometer logging | On or off, gated or continuous (3-axis accelerometer, ±8 g by default, up to ±16 g), with or without PPG captures |
| Skin temperature | On or off, skin-surface °C, 1 reading per minute by default |
| Time-window trigger | Start and end clock times |
| Rest-mode trigger | On or off, low-motion activation |
Duty cycle is the trade at the center of every study. By default, V2 captures PPG at 50 Hz for 45 seconds every 5 minutes. A longer on-time or a shorter interval gives you more signal, and more data to store and sync. Set it per state, so a sleep window can run dense while the rest of the day stays light.
04Sampling rates
What the model sees.
| Rate | What it unlocks |
|---|---|
| 25 Hz | Heart rate only. HRV and breathing rate (RR) degrade. |
| 50 HzDefault | Heart rate, HRV, breathing rate (RR) |
| 100 Hz | Heart rate, HRV, breathing rate (RR), PPG morphology |
Need the pulse shape itself? 100 Hz keeps the waveform detail used for morphology work.
05PPG wavelengths
Three wavelengths, switched on per state.
| Wavelength | Primary use |
|---|---|
| Green | 530 nm. Heart rate and HRV. Best at rest. |
| Red | 655 nm. SpO2, paired with infrared. |
| Infrared | 940 nm. SpO2. Standard in sleep mode. |
How green, red and infrared light read the pulse is covered on the science page.
06Who it is for
Partners who measure their own ground truth.
| Partner | Focus |
|---|---|
| Algorithm developers | Models that need a fixed signal contract. |
| Sleep research | Four-stage sleep (wake, light, deep, REM) research signal at a high duty cycle. |
| Clinical and academic research | Protocol-defined sensing windows. |
| Remote monitoring programs | Battery life, sync and signal density at fleet scale. |
One research wearable, configured four ways. A sleep study wearable runs dense through a nightly window. An algorithm team locks one signal contract across every device. A remote monitoring program keeps passive logging light so the fleet stays charged and in sync.
07What ships
Raw physiological signal in your format. White-glove configuration.
| Streams | Timestamps | Delivery | Configuration |
|---|---|---|---|
| PPG, accelerometer, skin temperature | UTC epoch. Nanoseconds for PPG, milliseconds for accelerometer | One CSV per stream | Set by Sensor Bio |
Raw files come through your organization's download from the Sensor Bio web platform, and live raw PPG is available through the mobile SDK. See raw data for file details.
ppg.csv
ts,green,ir,red- ts
- UTC epoch timestamp, nanoseconds
- green
- Raw green amplitude, AU, unfiltered. Default channel
- ir
- Raw infrared amplitude, AU, unfiltered. When enabled
- red
- Raw red amplitude, AU, unfiltered. When enabled
accelerometer.csv
ts,x,y,z- ts
- UTC epoch timestamp, milliseconds
- x, y, z
- Unfiltered axis values, m/s²
skin_temp.csvExample
ts,skin_temp_c- ts
- UTC epoch timestamp. Example
- skin_temp_c
- Skin-surface temperature, °C. Example column name
PPG and accelerometer fields match the V2 raw export. File names and the skin temperature columns are examples. Columns follow the wavelengths and streams you turn on.
08How configuration works
You define it. We apply it. The signal ships.
01 You define
What each device captures, when it captures, and at what fidelity, state by state.
02 We apply
Sensor Bio configures your sensors white-glove, based on how your team needs them set up, for your organization and, where your protocol needs it, for individual devices.
03 Signal ships
Raw PPG, accelerometer and skin temperature, one CSV per stream, with UTC timestamps.
FAQ
Questions, answered.
What can I configure on Sensor Bio V2?
Six parameters, each set per sensor state, per device and per organization: PPG duty cycle, PPG sampling rate (25, 50 or 100 Hz), accelerometer logging, skin temperature, a time-window trigger and a rest-mode trigger. You also choose which PPG wavelengths run: green, red and infrared. That level of control is what makes V2 a configurable research wearable rather than a fixed consumer tracker.
Which PPG sampling rate should I choose?
50 Hz is the default and covers heart rate, HRV and breathing rate (RR), reported in breaths per minute as resp_rate_brpm in the API. 25 Hz keeps heart rate but HRV and breathing rate degrade, so it suits light background logging. 100 Hz adds PPG morphology, the pulse shape itself, for teams building waveform models. Higher rates produce more data to store and sync.
What are the three sensor states?
Passive is the default baseline that governs background logging. Triggered turns on during a clock window or when the wearer is at rest, and it is tuned for the sleep-stage signal. Active runs during a workout or session started in the Sensor Bio app and has the highest throughput. Each state has its own configuration.
How do I set up a sleep study wearable configuration?
Use the Triggered state. Set a time-window trigger for the nightly sleep period, turn on the rest-mode trigger for low-motion periods, and run a high duty cycle with green and infrared PPG plus the accelerometer. Passive logging can stay light during the day. Sensor Bio applies the final configuration for your protocol.
Can different devices in one study run different configurations?
Yes. Configuration is set per organization and per device, so a study arm or cohort can run a different sampling rate, duty cycle or trigger window. Sensor Bio sets and applies these configurations for you.
What format does the raw data ship in?
One CSV per stream: PPG, accelerometer and skin temperature, each with UTC epoch timestamps. PPG files carry ts, green, ir and red, with raw amplitudes in arbitrary units and nanosecond timestamps. Accelerometer files carry ts, x, y and z, in m/s² with millisecond timestamps. Files come through your organization's download from the web platform, and live raw PPG is available through the mobile SDK.
Is Sensor Bio V2 a medical device?
No. Sensor Bio V2 is a general wellness device. It is not FDA cleared and is not intended to diagnose, treat, cure or prevent any disease. Configured data is for wellness, research and product development use.
Related
Protect the Signal.
Configure Sensor Bio V2 for your study.
Tell us your protocol. We set the configuration and ship the raw signal.
Sensor Bio V2 is a general wellness device. It is not FDA cleared and is not intended to diagnose, treat, cure or prevent any disease. Configuration options are set by Sensor Bio per organization. The study builder on this page is illustrative.