How to configure a research wearable

← Back to The Signal

How to configure a research wearable

Set sample rate, data cadence, active sensors, and raw export once in a device profile, then apply it across every wearer device before enrollment.

Quick answer: Configure a research wearable by locking sample rate (25, 50, or 100 Hz), data cadence, active sensors, and raw export in an organization device profile before enrollment, then apply that profile across every wearer device. Consumer defaults optimize battery and a fixed app; protocols need an explicit data model you can defend after last enrollment.

Why configure before enrollment?

A dashboard does not rescue a cohort collected at the wrong cadence. If the protocol needed high-frequency PPG and the devices wrote 15-minute summaries, you will not reconstruct the waveform later. The missing samples were never written.

Consumer defaults optimize battery and a fixed app experience. That is a reasonable product choice for a wellness wearer who wants a week between charges. Research and enterprise programs need the opposite posture: an explicit data model, applied consistently, with raw export available when analysis demands it.

Write the analysis question first. Name the features you will report (overnight rMSSD, respiratory rate from beat intervals, steps and cadence, a custom optical model). Then lock the capture profile that can actually produce those features. The research wearable checklist is the vendor-screen version of the same job. This page is the setup version: four controls, three example profiles, a rollout you can run before first kit, and the failure modes that show up after week one.

Sensor Bio Device Config sits in the Build layer of the Capture, Connect, Build, Act stack. Capture is the hardware. Connect is the SDK and API path into your app or warehouse. Build is the org profile you set once. Act is Signal Studio and the adherence views that fire only after the signal exists.

If you skip Build and jump to Act, you are writing rules on whatever the consumer default happened to store.

What belongs in the device profile?

Think in four controls. They interact. Changing one without naming the others is how programs end up with 100 Hz capture and a 15-minute review cadence, or raw export on and no Super Admin who can pull the files.

Together these controls are part of 100+ configurations you can set once for the organization. You will not use all of them. You will use a small, named subset that matches the protocol.

Sample rate

Organizations set optical sample rate at 25, 50, or 100 Hz. The default is 50 Hz. The setting is org-level, not a per-wearer slider in a consumer settings screen.

Pick from the protocol, not from a marketing default.

RateWhen it is a reasonable illustrationWhat you pay
25 HzLighter program monitoring where computed metrics are enoughLowest power and storage among the three
50 Hz (default)General research and product capture when you have not proven a need for 100 HzThe published default posture
100 HzWaveform detail, algorithm work, or a pipeline that will re-derive beatsHighest power and storage among the three

A profile that is too coarse cannot be fixed after enrollment if the raw signal was never stored. Upsampling a 25 Hz file does not invent the samples you skipped. Downsampling a stored 100 Hz file later is easy. The reverse is not.

That asymmetry is why algorithm and model programs often start at 100 Hz for a short validation window, then decide whether the extra rate is worth the battery and storage cost for the full cohort. Overnight recovery programs that only need computed HRV and sleep-adjacent metrics often stay at the 50 Hz default. Motion-forward activity programs that treat PPG as a secondary channel sometimes drop to 25 Hz. Copy the pattern only after the analysis plan says it belongs there.

Higher sample rates, more raw channels, and continuous capture shorten the week. Published V2 comparison figures are planning bounds, not promises for every duty cycle: 5 to 7 days of battery under default settings versus about 2 days under max recording, and on-device storage of about 2.5 days default versus about 1.2 hours under max recording. Put the bound that matches your profile into the participant charge instructions before kits ship.

For the optical background behind the rate choice, see photoplethysmography (PPG). For the partner file shape, see raw PPG access.

Data cadence

Cadence is how often data leaves the device path into your workflow. It is not the same as sample rate. Sample rate is how densely the optical (or motion) channel is written. Cadence is how often that writing shows up in the product, warehouse, or operator view.

Documented cadence examples:

  • Live
  • 1 minute
  • 5 minutes
  • 15 minutes

Live supports coaching and product features. It also supports the first week of ingestion validation, when you want to see a stream land in your schema before you trust a nightly batch. Longer cadences reduce chatter for overnight or population programs. State the choice in the protocol.

CadenceFitsFailure mode if you pick it for the wrong job
LiveCoaching, in-product feedback, connector validationSync and review noise on a large cohort that nobody watches live
1 minuteTight program review while you still want batch-like structureStill chatty if coaches only open the console twice a day
5 minutesOvernight or population programs without live coachingToo slow if a product feature needs a current heart-rate tile
15 minutesLow-urgency population viewsToo coarse if you planned to catch short sessions or charge gaps in near real time

A common mismatch: the protocol says "continuous physiology" and the profile writes 15-minute summaries. Continuous capture at 50 or 100 Hz with a 15-minute export cadence can still be a valid research posture, as long as the raw or computed record is stored at the rate you need. Continuous capture with only 15-minute derived tiles and raw off is a different product. Name which one you bought.

If live streaming is the product job, read real-time physiological data streaming after you lock the profile. Cadence is a product choice. It is not a footnote for IT.

Sensor toggles

Turn on only what the program needs:

  • PPG
  • Motion
  • Skin temperature

Unused channels still cost power and review time. Toggle with intent.

PPG is the optical path. On V2, published wavelength centers are green 530 nm, red 655 nm, and infrared 940 nm. Green is the default primary channel for heart-rate and HRV-style pipelines. Infrared and red appear when configured. You do not need every wavelength on for every program.

Motion is the accelerometer path. Raw accel is a separate enable: x, y, z in m/s² with millisecond timestamps. Use it when artifact review or activity features are in scope. A motion-forward program that never enabled the raw accel channel will still see computed steps and cadence if those on-device outputs are on. It will not be able to reopen the three-axis trace later.

Skin temperature is optional. Leave it off unless the endpoint or coaching view uses it. "We might want it later" is not a toggle rationale. Later you can turn it on for the next cohort. You cannot backfill a channel that was dark.

On-device computed outputs (when you leave raw off, or when you store both) include heart rate, HRV as rMSSD, respiratory rate, steps, cadence, and beat-to-beat intervals. On-device and near-device SDK options also cover sleep staging, HRV, beat-to-beat, and active minutes. Know which layer owns the number you will report. Configuration is how you decide whether that number is the only thing you stored.

Raw export on or off

Raw export is the difference between rebuilding features later and being stuck with someone else's scores.

Leave it on when models, validation, or re-analysis are in scope. Leave it off when the program only needs on-device computed metrics and you want the lighter power and storage posture.

Two operational facts matter before first enrollment:

  1. Raw PPG is disabled by default in both Passive (awake) and Rest Mode (sleep). Turn it on for the organization if the protocol needs waveforms. Forgetting this is a quiet failure. The devices look healthy. The computed tiles look fine. The raw download is empty.
  2. Raw downloads and computed downloads are different jobs. Computed windows are 1-30 days per request. Raw windows are 1-7 days. Concurrent download jobs are limited to 3 per organization. Links expire and can be refreshed. Super Admin is required for those batch pulls. REST lives at https://api.sensorbio.com/v1/ with an API key header. Confirm field names on Developers before you freeze a connector.

Raw PPG fields, when enabled:

FieldMeaning
tsNanosecond timestamp
greenUnfiltered green amplitude (AU)
irUnfiltered infrared amplitude (AU), when enabled
redUnfiltered red amplitude (AU), when enabled

No filtering is applied in that raw package. Green is the default primary. You can store computed metrics alongside raw. Many programs do.

If you only need beat-to-beat intervals and computed HRV, say so. Do not pay the max-recording side of the battery and storage bounds without a use for the waveform.

For research and product teams

Put the raw signal in your study or product

If you already know you need waveform export and a locked sample rate, we can walk the capture profile before first enrollment.

Which example profiles fit common protocols?

These are workflow illustrations for general wellness and research operations. They are not care protocols and they do not set treatment cutoffs. Use them to see how the four controls move together, then write the profile your protocol actually needs.

Overnight recovery monitoring

Job: collect nights you can reopen, with enough motion context to explain bad windows, without forcing live coaching.

Illustration:

  • PPG on. Motion on. Skin temperature only if the program view uses it.
  • Sample rate at the 50 Hz default unless the analysis plan already proved a need for 100 Hz.
  • Cadence at 5 or 15 minutes. Live is usually out of scope if nobody is coaching overnight.
  • Raw export on if you will re-derive features or audit optical quality. Raw export off if overnight rMSSD, respiratory rate, and sleep staging from on-device or SDK outputs are the entire endpoint list.
  • Confirm Rest Mode raw is actually on. Defaults keep raw off during sleep. An overnight program that forgets this setting collects computed sleep tiles and no waveform.

Charge and storage planning: if raw is off and you stay near default capture, the published 5 to 7 day / ~2.5 day battery and storage bounds are the planning envelope. If you turn raw on at a high rate and continuous capture, plan against the ~2 day / ~1.2 hour max-recording envelope and write a nightly charge-and-sync instruction participants will follow. Do not quote the 5 to 7 day figure in a consent form for a max-recording profile.

Operator view: adherence watchlists on wear time and nights with a valid window. Signal Studio rules wait until you have confirmed that nights are landing.

Algorithm and model development

Job: store the optical amplitudes and motion context so a model team can re-derive beats, train, and fail in a notebook instead of in production.

Illustration:

  • PPG on at a high sample rate. 100 Hz is the research-oriented example when waveform detail matters.
  • Raw export on. Green on. Add infrared and red if the model uses those wavelengths. Know that each extra raw channel costs storage.
  • Motion on, including the separate raw accel enable, so artifact windows have a three-axis trace next to the optical file.
  • Cadence live or 1 minute while you validate ingestion. After the connector is trusted, you can relax cadence for the rest of the cohort without turning raw off.
  • Super Admin identified before the first pull. A model team without download rights will ask you for files you cannot hand over.

Validate one short capture end to end before you enroll anyone: device, sync, raw file or API response, your schema. Confirm ts, green, and any enabled ir / red columns. Confirm accel x, y, z if you enabled it. Confirm the sample interval matches 100 Hz (or 50, or 25), not the default you thought you had overridden.

Power note: this profile sits closer to the max-recording side of the published bounds. Budget charging in the lab SOP and in any at-home collection window. On-device storage of about 1.2 hours under max recording is a logistics fact, not a footnote. If the phone is out of range and the device is writing raw at max settings, you can lose the window you meant to keep. Plan the sync path before you enroll.

Motion-forward activity program

Job: activity features coaches can review, with PPG only if heart-related program metrics are actually in the protocol.

Illustration:

  • Motion on. Enable raw accel if you will reopen the trace. Leave raw accel off if computed steps, cadence, and active minutes are enough.
  • PPG on if the program reports heart rate or HRV-style metrics. PPG off if the program is steps, cadence, and wear time only.
  • Sample rate 25 or 50 Hz when PPG is on and you do not have a waveform-detail requirement.
  • Cadence matched to how often coaches review. If the console is opened twice a day, 5 or 15 minutes is enough. If a live tile is part of the product, use live.
  • Raw PPG export optional. Turn it on only if someone named a re-derivation job.

This is the profile that gets over-specified. Teams copy the algorithm profile "just in case" and then wonder why battery and storage collapsed. If the analysis plan does not mention optical morphology, do not pay for it.

How should you roll out a profile before enrollment?

Do this in order. Skipping a step is how you discover the wrong rate after week three.

  1. Draft the profile against the protocol, not against a sales slide. Write sample rate, cadence, sensor toggles, raw on/off, and which wavelengths and accel channels are enabled. Name the owner.
  2. Apply the profile across devices for the org. Org-level means every wearer device should inherit the same capture model. If a phone app can silently change sampling, your warehouse becomes a mixture of protocols.
  3. Issue SDK and API keys from the admin console. iOS uses SPM. Android uses Kotlin Flow BLE SDKs. Cloud jobs use REST at https://api.sensorbio.com/v1/ with an API key header. Keep key holders on a short list.
  4. Confirm streams in your app, warehouse, or notebook. One canary device. One short session. One raw window if raw is on. One computed window. Check timestamps, units, and that Passive and Rest Mode both match the written profile.
  5. Confirm download ops. Super Admin can pull. Windows fit the 1-7 day raw and 1-30 day computed limits. Orchestration stays at or under 3 concurrent jobs. Someone knows that expired links can be refreshed.
  6. Write the charge and sync instruction that matches the profile. Default-settings language for a default profile. Max-recording language for a max-recording profile. Do not mix them.
  7. Only then attach Signal Studio rules and adherence watchlists. Configuration decides what exists. Rules decide who gets notified. Watchlists show who needs follow-up on wear time, sleep, and activity without another survey.

Get started is the product path when you want keys and a walkthrough. The live reference for endpoints is developers.sensorbio.com. Freeze connectors against that host, not against this page.

What failure modes show up after week one?

These are the ones that show up after the kickoff deck is closed.

Raw still off in Rest Mode. The overnight program looks fine in computed tiles. The raw download for sleep windows is empty. Defaults keep raw off in Passive and Rest Mode. Check both.

Sample rate left at default while the SAP assumed 100 Hz. Org default is 50 Hz. If nobody set 100 Hz, you have 50 Hz. You will not notice until a model owner opens the file.

Cadence treated as sample rate. A live cadence with raw off still does not store a waveform. A 15-minute cadence with raw on can still store 100 Hz amplitudes. Write both numbers.

No Super Admin for downloads. The profile is correct. The files exist. The analyst cannot pull them. Role design belongs in the rollout, not in a ticket after first monitoring visit.

Max-recording capture with default-settings charge copy. Participants were told "about a week." The profile is closer to the ~2 day battery and ~1.2 hour storage bounds. Dropout after week one is then a configuration error, not an adherence mystery.

Rules before signal. Signal Studio on an empty or wrong stream produces noise. Configure, validate, then add alerts.

Changing the profile mid-cohort without a version note. You can update an org profile. You cannot reconstruct nights collected under the old one. Version the capture model in the data dictionary the same way you version a schema. See digital biomarkers for the endpoint-side version of that discipline.

Docs drift. Field names and routes move. Re-check developers.sensorbio.com before each major pull. This page states product facts. It is not the API reference.

How does configuration connect to action?

Configuration decides what exists. Signal Studio decides who gets notified. Adherence watchlists show who needs follow-up on wear time, sleep, and activity.

The API shape behind the streams is in raw PPG access. The buyer-language version of the same four questions is in how to choose a wearable for research. When the program is a trial-style RFP, use wearables for clinical trials. When the product question is REST versus SDK versus aggregator, use wearable API for health products.

Do the unglamorous part first. Lock the profile. Validate one device. Then enroll.

FAQ

What can you configure on a Sensor Bio device profile?
Sample rate (25, 50, or 100 Hz), data cadence (live through multi-minute batch), which sensors are active (PPG, motion, skin temperature), and whether raw export is on. Profiles apply across devices for your organization.
Why does sample rate matter for research wearables?
Sample rate bounds what algorithms and analyses can recover later. A profile that is too coarse cannot be fixed after enrollment if the raw signal was never stored.
Is this the same as a consumer wearable setting screen?
No. Consumer apps optimize for a fixed wellness experience. Research and enterprise programs need a data model you set once, then enforce across every wearer device.
How does configuration connect to alerts?
Configuration decides what is collected and how often. Signal Studio uses that signal to notify coaches or operators. Configure first, then add rules.
When should I turn raw PPG export on?
Turn it on before enrollment when models, validation, or later re-analysis need the waveform. Raw PPG is off by default in Passive and Rest Mode. Skip it if you only need on-device computed metrics.
Can I change the profile after people are already enrolled?
You can change an org profile later, but you cannot reconstruct a waveform that was never stored. Treat the first-enrollment profile as the protocol. Validate on a canary device before you roll a change to the full cohort.