Which wearables expose raw PPG, IBI, or summaries only, and how: Sensor Bio V2 multi-wavelength raw via SDK and per-org download, plus a sourced access matrix across Empatica, Polar, Garmin, Apple, Fitbit, Oura, Whoop, Samsung and Corsano.

Quick answer: Raw PPG access means you can store optical amplitudes, not only a heart-rate score. Sensor Bio V2 exposes green, red and infrared channels at 25, 50 or 100 Hz through the Mobile SDK raw stream and a per-organization download (opt-in). Other wearables differ: some ship BVP or IBI, some only summaries. The matrix below is sourced from current public vendor docs.

Also see raw PPG data access on Sensor Bio, the raw data integration path, and the wearable API overview.

Raw access by wearable

Use this table when a protocol or product brief asks which device can actually hand you a waveform. "Not documented publicly" means the fact was not found on that vendor's public developer docs when checked; it does not prove the capability is absent behind a private contract.

Full rawoptical amplitudes / PPG channelsPartialIBI, BVP, or limited raw pathsSummaries onlyscores and derived samples
DeviceRaw PPGWhat public docs exposeHow you get itSources
Sensor Bio V2PinnedFull raw

Raw green, red and IR PPG (two photodiodes); accel separate; beat-to-beat on Mobile SDK.

Details

Default duty cycle 50 Hz for 45 s every 5 min (white-glove config). About 5 to 7 days battery under default settings. Field names in the raw package: ts, green, ir, red.

Mobile SDK raw stream (iOS/Android) and per-organization web download (opt-in, off by default). REST API for summaries and org management.

Details

Docs: developers.sensorbio.com

1
Empatica EmbracePlusPartial

Cloud raw includes BVP (optical absorption), accel, EDA, gyro, temperature as Avro. Not separate green/red/IR photodiode channels.

Details

Academic FAQ: no SDK and no live stream. Enterprise/RPM: platform SDK and Cloud API when contracted.

Empatica Cloud raw download; enterprise SDK/API when contracted.

2
Polar Verity SenseFull raw

PPG values, PP interval, accel, gyro, magnetometer; SDK mode PPG rates include 28-176 Hz.

Details

Offline recording supported on recent firmware.

Polar BLE SDK streaming and offline recording.

3
Polar OH1Full raw

PPG values, PP interval, accelerometer (about 50 Hz).

Polar BLE SDK

3
Garmin (Health stack)Partial

Enhanced beat-to-beat / heartBeatIntervals on supported Health API, Health SDK and Connect IQ paths.

Details

Continuous raw PPG / multi-wavelength waveforms are not listed on those public pages.

Garmin Connect Developer Program Health API; licensed Health SDK; Connect IQ.

4
Apple WatchSummaries only

HealthKit derived samples. Continuous raw PPG is not a HealthKit data type.

Details

SensorKit PPG needs an Apple-approved research entitlement; SensorKit data cannot be used to develop a commercial product.

HealthKit on iOS; SensorKit for entitled research.

5
Fitbit / Google Health APISummaries only

Derived heart rate and wellness metrics. Raw PPG and beat-to-beat IBI are not listed in the public Google Health API data types.

Details

Legacy Fitbit Web API was turned off (HTTP 410).

Google Health API after Google OAuth and review.

6
OuraSummaries only

Daily scores, sleep summaries and 5-minute heart-rate samples on Cloud API v2.

Details

Continuous raw PPG, raw accelerometer, beat-to-beat IBI and an on-device streaming SDK are not listed on that public surface. Organizations export may differ; confirm with Oura.

Oura Cloud API v2

7
WhoopSummaries only

Scored Recovery, Strain, Sleep and Workout objects on the public Developer API.

Details

Continuous raw PPG, beat-to-beat intervals and continuous intraday HR series are not listed on the public OpenAPI docs. Research Unite terms are separate.

WHOOP Developer API

8
Samsung Galaxy Watch (Health Sensor SDK)Full raw

Raw PPG green, IR and red via PPG_CONTINUOUS at 25 Hz; PPG_ON_DEMAND at 100 Hz; HEART_RATE_CONTINUOUS includes IBI.

Samsung Health Sensor SDK specs

9
Corsano CardioWatchFull raw

Raw PPG (green / red / infrared), accelerometer and ECG export documented for research.

Details

Research Portal CSV, REST API and Bluetooth SDK (Connection Package). Public product pages do not list a self-serve wellness SDK default.

Corsano research/commercial packages.

10
  1. Sensor Bio developer docs - Mobile SDK and API reference.
  2. Empatica raw data; research studies FAQ. Reviewed 2026-11-08.
  3. Polar Verity Sense; Polar OH1 BLE SDK product docs.
  4. Garmin Health API; Health SDK. Reviewed with Sensor Bio comparison evidence 2026-10/11.
  5. Apple HealthKit; Apple Research & Care FAQ (SensorKit limits).
  6. Google Health API / Fitbit migration docs. Raw PPG and IBI not listed on the public data-type surface reviewed for Sensor Bio Fitbit comparison.
  7. Oura Cloud API v2 public docs.
  8. WHOOP Developer API.
  9. Samsung Health Sensor SDK data specifications (PPG_CONTINUOUS, PPG_ON_DEMAND).
  10. Corsano CardioWatch public research/API documentation as summarized on Sensor Bio's Corsano comparison evidence (2026-10/11). Confirm current package terms with Corsano.

Updated November 8, 2026. Re-verify before you lock a protocol. For Sensor Bio product wiring see raw data and the wearable API. For the science framing of what "raw" means on V2, see /science/#raw-ppg-data.

What raw PPG access means here

Raw PPG access means you can store the optical amplitudes themselves. Not only a heart-rate number. Not only a recovery score.

Partners use that for custom algorithms, quality review, and re-analysis after the first pass. If you cannot reopen the waveform, you cannot change a filter, hand a segment to a collaborator, or defend a derived feature when someone asks how it was built.

Research workflows often ask for about 100 Hz when waveform detail matters. Sensor Bio lets the organization choose 25, 50, or 100 Hz (default 50 Hz). Match the rate to the protocol. Do not default to the maximum without a reason. Power and on-device storage fall as the rate and the raw channels rise.

This is a capture-profile decision, not a dashboard toggle you flip after first enrollment. Lock it with the rest of the device profile. How to configure a research wearable covers sample rate, cadence, and sensor toggles. Digital biomarkers for program design is the endpoint-first version of the same argument.

When you actually need the waveform

You need raw amplitudes when at least one of these is true:

  • You will write or swap a beat detector, filter, or quality model after data collection starts.
  • A reviewer or partner will ask to see the optical record, not only rMSSD or heart rate.
  • Morphology features (rise time, amplitude envelope, multi-wavelength ratios you compute yourself) are in scope.
  • You do not want the on-device derivation to be the only durable artifact.

You do not need raw amplitudes when the protocol is satisfied by stored beat-to-beat intervals plus computed heart rate, rMSSD, respiratory rate, steps, or cadence. Say that out loud. Raw is a cost. Pay it when you will open the file.

For optical background, use PPG for wearable products and PPG signal quality. For product-side wiring, wearable API for health products sits next to this page.

What you get in the file

Per-organization raw data downloads from the web platform (1-7 day window per request) include PPG as:

FieldMeaning
tsNanosecond timestamp
greenRaw green amplitude (AU), unfiltered
irRaw infrared amplitude (AU), when enabled
redRaw red amplitude (AU), when enabled

Those four names are the language already used for this package. Confirm them on the Mobile SDK raw stream and on the web platform download against Developers before you freeze a parser. Field details move. This page states product facts from the Metrics Overview. If the live reference and this article ever disagree, trust the live reference and file the difference.

No filtering is applied in that raw package. The values are arbitrary units (AU). Do not treat AU as a calibrated blood-volume number. Do not compare raw amplitude across hardware generations or strap positions as if it were a lab concentration.

Wavelengths on V2

On V2 hardware, published wavelength centers are:

  • Green: 530 nm (default primary channel)
  • Red: 655 nm
  • Infrared: 940 nm

Green is the default primary channel for heart rate and HRV style pipelines. Infrared and red appear when those channels are enabled on the profile. If your algorithm expects a three-color stack, write the enable into the organization profile. A green-only file is not a bug if you never turned the other two on.

Wavelength center is not a validation study. It tells you which LEDs the hardware publishes. Your own protocol still has to say how you handle motion, perfusion, and contact.

Accelerometer is a separate package

Accelerometer raw (x, y, z in m/s² with millisecond timestamps) is a separate enable when motion context matters for artifact review. It is not a column in the PPG table above.

That split is easy to miss. Teams enable raw PPG, pull ts / green / ir / red, then wonder where the accel went. If you will reject windows with high motion, enable accel raw on purpose and join on time in your pipeline. PPG timestamps are nanosecond. Accel timestamps are millisecond. Decide the join tolerance in the data dictionary, not in a notebook comment after first patient in.

Computed biometrics are a third path: heart rate, HRV (rMSSD), respiratory rate, steps, cadence, beat-to-beat intervals, plus sleep staging and scores from the layers that own them. Those use the computed download window (1-30 days), not the raw 1-7 day window. Many partners store both.

How to turn it on

Defaults favor lighter capture. Raw PPG is off in both Passive (awake) and Rest Mode (sleep) until you enable it. 50 Hz is the default sample rate. Research and product partners opt in.

Do this before kits ship:

  1. Set the organization sample rate to 25, 50, or 100 Hz. Pick from the analysis plan. 100 Hz if waveform detail is in scope. 50 Hz if you want the published default. 25 Hz if the protocol is light and you have a reason.
  2. Enable raw PPG for the profiles that need it. Say whether that is Passive, Rest Mode, or both. A morphology study that only turns on overnight raw will not have daytime waveforms. That may be correct. Write it down.
  3. Enable infrared and red if the algorithm needs them. Green-only is the usual HR / HRV starting point.
  4. Enable accelerometer raw if artifact review needs x, y, z.
  5. Confirm who holds Super Admin for web platform downloads. Raw and computed batch pulls require that role.
  6. Validate one short capture end-to-end before first enrollment: device, then sync, then the web platform download or the Mobile SDK raw stream, then your schema. Open the file or the stream sample. Check that ts is present, green is populated, and ir / red match what you enabled.

If step 6 produces an empty raw package, you enabled the wrong profile or you pulled the computed path by mistake. Fix it on a staff device. Do not debug this on participant week two.

Site-style programs should put the on-switch in site initiation, not in a late protocol amendment. The same advice shows up in wearables for clinical trials and the shorter research wearable checklist.

For research and product teams

Put the raw signal in your study or product

If you already know you need the raw waveform and a locked sample rate, we can walk the capture profile before first enrollment.

Paths into your stack

V2 raw multi-wavelength PPG (green, red, infrared) is available today through two routes: the Mobile SDK raw stream (iOS and Android) and a per-organization raw data download from the web platform, enabled per organization. Pick the route from where the handset sits in your trust boundary.

REST API

The REST API serves computed metrics, not V2 raw PPG.

Cloud patterns for user management, computed metric retrieval, and organization administration use the REST API at https://api.sensorbio.com/v1/ with an API key authorization header. Those patterns are documented on API. V2 raw waveforms stay on the Mobile SDK raw stream and the web platform download. Store API keys in a secret manager. Super Admin for web platform downloads and API key holders are different roles. Write both down.

If the phone is outside your trust boundary and you already run a warehouse, pull V2 raw PPG from the per-organization web platform download. Queue those jobs the same way you queue any file pull.

Mobile SDK

V2 raw multi-wavelength PPG (green, red, infrared) is available today through the Mobile SDK raw stream on iOS and Android.

Native BLE SDKs wrap the radio protocol for iOS (SPM) and Android (Kotlin Flow). Use them when the handset is part of the product: pairing, live display, on-device processing, or a workflow that should work before the cloud job finishes.

On-device algorithm SDKs cover sleep staging, HRV, beat-to-beat intervals, and active minutes when you want processing beside the handset. That is a different artifact from raw PPG. You can run both. You can run neither and wait for cloud computed downloads. Pick from whether the phone is allowed to see the signal.

Start from the SDK reference and the Get started path when you are issuing keys for a new org. For streaming-shaped product work, real-time physiological data streaming is the adjacent Signal piece.

Batch export

V2 raw multi-wavelength PPG is available today as a per-organization raw data download from the web platform, enabled per organization. CSV and JSON downloads support partner and study ops workflows without writing a full connector on day one. Raw windows are 1-7 days per request. A 28-day series is at least four jobs. Computed windows are 1-30 days. Concurrent jobs are limited to 3 per organization. Put a queue in front of the client. A naive loop that fires one job per participant will stall. Links expire and can be refreshed. Do not archive the signed URL as if it were the data. Archive the file.

Batch is the right first step when:

  • You need to prove the file lands in a statistician's folder this week
  • The warehouse connector is not staffed yet
  • You are validating column names before you generate types

It is the wrong last step when you have hundreds of participants and three concurrent jobs. Orchestrate. Chunk by day range. Keep a manifest of which window landed for which user.

A worked pull (one staff device)

You do not need a cohort to test this. You need one configured device and one destination table.

  1. Set the org to 50 Hz (or 100 Hz if that is the protocol).
  2. Enable raw PPG in Passive and Rest Mode. Leave IR/red off if the first pipeline is green-only.
  3. Wear the device for a few hours, including some walking so you have motion in the record.
  4. Sync.
  5. As Super Admin, request a per-organization raw data download from the web platform for a 1-day window. CSV is fine.
  6. Open the file. You should see ts, green, and empty or absent ir / red if you left those off.
  7. Request a computed download for the same day. Confirm heart rate or intervals exist alongside the waveform, not instead of it.
  8. Drop both files into the schema you will use for the study. Join on time. Plot a two-minute window. If you cannot find a pulse-like oscillation in green during a still segment, fix wear or enable before you ship kits.

That loop is the difference between "we have raw access" as a slide and raw access as a pipeline.

Honest constraints

Raw access does not make wrist optics easy. It makes the difficulties visible.

  • Motion and perfusion still dominate wrist optical quality. Raw access does not remove artifact. It lets you see it. Walking, clasp looseness, cold skin, and contact changes will still wreck segments. Pair the waveform with accel when you will reject those windows. Read PPG signal quality before you promise a completeness rate.
  • Power and storage fall as sample rate and raw channels rise. V2 comparison figures show 5 to 7 days of battery under default settings versus about 2 days under max recording settings. On-device storage is about 2.5 days default versus about 1.2 hours at max recording. Treat those as planning bounds. A 100 Hz, three-wavelength, raw-on profile needs a charging and sync SOP participants will follow. Put it in the instructions.
  • Defaults favor lighter capture. Raw off and 50 Hz are intentional. A partner who forgets the enable will collect computed biometrics and then ask where the waveform is. You will not find one. Enable before enrollment.
  • Windows and concurrency are small on purpose. Raw pulls are 1-7 days. Three jobs at a time. Design the queue. Do not assume a single "download everything" button.
  • Timestamps differ across packages. PPG raw ts is nanosecond. Accel raw is millisecond. Computed series have their own cadence (live, 1, 5, 15 min, plus whatever the metric's own window is). Your join code is part of the biomarker.
  • AU is unfiltered and uncalibrated. Do not publish raw amplitude thresholds as physiology. Do not put diagnostic cutoffs in public copy. V2 is a general wellness device, not FDA cleared for diagnosis.
  • Field details move. Confirm ts, green, ir, and red on the Mobile SDK raw stream and the web platform download against developers.sensorbio.com before you freeze a parser. The field table on this page matches the language already used for this package. Recheck it when you pin a schema.

If you only needed intervals, you paid a lot of battery to stare at a waveform you will never plot. Go back to the capture profile and turn raw off.

Request signal access when you are ready for keys and a walkthrough. Read the technical brief on developers.sensorbio.com for the Mobile SDK raw stream and the web platform download.

FAQ

What is included in Sensor Bio raw PPG export?
Unfiltered PPG amplitudes for green, infrared, and red (when enabled), with nanosecond timestamps, in arbitrary units. Green is the default primary wavelength. Field names in the raw package are ts, green, ir, and red.
What sample rates are available?
Organizations can configure 25, 50, or 100 Hz. The default is 50 Hz. Choose from the analysis plan; higher rates cost power and storage.
How do partners pull raw PPG into their stack?
V2 raw multi-wavelength PPG (green, red, infrared) is available today through the Mobile SDK raw stream (iOS and Android) and a per-organization raw data download from the web platform, enabled per organization. Web platform raw downloads use 1-7 day windows and require Super Admin.
Is raw PPG on by default?
No. Raw PPG is disabled by default in Passive and Rest Mode. Enable it for the organization before enrollment if your pipeline needs waveforms.
What wavelength centers does V2 publish?
Published V2 wavelength centers are green 530 nm, red 655 nm, and infrared 940 nm. Green is the default primary channel for heart rate and HRV style pipelines.
Does the raw PPG package include accelerometer?
No. Accelerometer raw (x, y, z in m/s² with millisecond timestamps) is a separate enable when you need motion context for artifact review.
Which wearables expose raw PPG to developers?
Public docs currently list raw or near-raw optical access for Sensor Bio V2 (SDK stream and per-org download), Empatica EmbracePlus (Cloud Avro BVP and related streams; academic plans have no SDK), Polar Verity Sense and OH1 (Polar BLE SDK), Samsung Galaxy Watch via the Health Sensor SDK (PPG_CONTINUOUS), and Corsano CardioWatch research packages. Many consumer APIs document summaries or IBI only. See the access matrix on this page and the linked vendor docs.
Do consumer wearable APIs return raw PPG or only summaries?
It depends on the vendor. WHOOP, Oura Cloud API v2, Fitbit/Google Health API, and Apple HealthKit publicly document derived summaries or samples; continuous raw PPG waveforms are not listed on those public surfaces. Garmin lists enhanced beat-to-beat intervals for approved Health API/SDK partners, not continuous raw PPG. Always re-check the vendor's current developer docs.
Can I get beat-to-beat IBI without raw PPG?
Often yes. Several platforms expose IBI or RR-style intervals without shipping the optical waveform. Sensor Bio Mobile SDK streams include beat-to-beat alongside the optional raw PPG stream. Garmin Health SDK and Connect IQ document heartBeatIntervals / enhanced beat-to-beat on supported paths. Confirm units and gaps before you treat IBI as a substitute for waveform review.
Which devices support overnight raw pulse recording?
Overnight capture is a wear-schedule and duty-cycle question as much as an API question. Sensor Bio V2 can enable raw PPG in Rest Mode with a configured sample rate; default duty cycle is 50 Hz for 45 seconds every 5 minutes with white-glove changes per organization. Polar Verity Sense documents offline PPG recording through the BLE SDK. Empatica EmbracePlus records continuous streams into Empatica Cloud Avro files. Consumer rings and watches often store overnight metrics without exposing overnight raw PPG on public APIs.
Can I stream raw PPG into my own app over BLE or an SDK?
Sensor Bio V2 streams raw multi-wavelength PPG through the Mobile SDK on iOS and Android. Polar Verity Sense and OH1 stream PPG over the Polar BLE SDK. Samsung Health Sensor SDK exposes PPG_CONTINUOUS on supported Galaxy Watch models. Empatica's academic FAQ states there is no SDK for academic research; enterprise/RPM paths document an SDK. Apple SensorKit PPG is research-entitlement gated and cannot be used to develop a commercial product per Apple's research FAQ.