Wearables for clinical trials

← Back to The Signal

Wearables for clinical trials

Buyer guide to wearable data access for clinical trials: raw signal, exports, APIs, wear-time, and evidence questions without black-box lock-in.

Quick answer: For clinical trials, buy data access and operations you can defend, not a consumer score. Put raw signal rights, exports, configuration control, and wear-time reporting in the RFP before industrial design debates. After last patient out, the durable asset is the signal your statisticians can still reopen.

After last patient out, the asset is the signal

The only durable thing a wearable trial leaves you is what you can still analyze. If the vendor cloud will only show a recovery index, your statistician cannot reopen the optical record. If exports expire into a proprietary viewer, your archive is a screenshot.

Trial teams do not need another wellness app. They need a contract with the signal: which channels leave the device, in which format, at which rate, under which role, for how long after closeout.

Write that contract before first kit ships. A late protocol amendment that says "please turn raw on" does not recover week one.

This page is the RFP version of the job. The shortlist version is how to choose a wearable for research. The setup version is how to configure a research wearable. The endpoint-definition version is digital biomarkers.

What to put in the RFP

Treat the wearable as a data vendor. Ask for written answers. If the answer is a slide with a single accuracy number, you do not have an answer yet.

Raw and derived channels

Spell the channels. Do not accept "we capture heart rate."

  • Raw PPG waveform when morphology or re-derivation is in scope
  • Beat-to-beat intervals when timing analyses matter
  • Motion for artifact context
  • Skin temperature if your endpoints use it
  • Which wavelengths (green, red, infrared) must be on

For Sensor Bio, raw PPG downloads expose unfiltered green, infrared, and red amplitudes with nanosecond timestamps when those channels are enabled. Field names in the raw package are ts, green, ir, and red. Green is the default primary channel. On V2 hardware, published wavelength centers are green 530 nm, red 655 nm, and infrared 940 nm. Sample rate is organization-configurable at 25, 50, or 100 Hz (default 50 Hz).

Raw PPG is off by default in Passive (awake) and Rest Mode (sleep). Enable it before enrollment if the protocol needs waveforms. Accelerometer raw is a separate enable: x, y, z in m/s² with millisecond timestamps. Ask for it when artifact review is in scope.

Write the on-switch into site initiation, not into a late amendment. A vendor who says "we have raw" and ships with raw off in sleep will give you computed nights and an empty waveform archive.

ChannelWhen a trial actually needs itSensor Bio fact to confirm in writing
Raw PPG (ts, green, ir, red)Re-derivation, morphology, optical audit, model workOff until enabled. Org sample rate 25 / 50 / 100 Hz
Beat-to-beat intervalsTiming analyses that stop short of the waveformOn-device computed path exists. Confirm cadence
Computed HR, rMSSD, respiratory rateProtocol uses those features as stored outputsComputed download window is 1-30 days
Steps, cadenceActivity or adherence endpointsCadence examples: live, 1 min, 5 min, 15 min
Accel raw (x, y, z)Artifact review, motion-forward analysesSeparate enable. Millisecond timestamps
Skin temperatureEndpoints that name itSensor is on the device. Confirm export in the profile

If your analysis plan stops at heart rate, rMSSD, respiratory rate, steps, or cadence, say so. Do not pay the power and storage cost of raw capture without a use for it. Partner file details live in raw PPG access. Optical background lives in photoplethysmography (PPG).

Export and API contracts

A waveform you cannot land in the warehouse is a waveform you do not have. Ask for:

  • Formats (CSV/JSON at minimum)
  • Pull windows and rate limits
  • REST or cloud-to-cloud automation
  • Mobile SDK behavior if the phone mediates sync
  • Retention and re-download rules after the study ends
  • Who is allowed to pull (role, not "someone on our team")

Sensor Bio's documented path includes REST at https://api.sensorbio.com/v1/ with an API key header, iOS (SPM) and Android (Kotlin Flow BLE) SDKs, OAuth 2.0 consent flows for third-party apps, computed downloads over 1-30 day windows, and raw downloads over 1-7 day windows. Super Admin role is required for those batch downloads. Concurrent jobs are limited to 3 per organization. Links expire and can be refreshed.

Put role design in your study ops plan. If the only person who can pull raw is a vendor CSM, you do not have an archive. You have a ticket queue.

PathWhen it fits a trialConstraint to write down
Batch CSV / JSONData management and partner validation before a full connector shipsComputed 1-30 days. Raw 1-7 days. 3 concurrent jobs
REST at https://api.sensorbio.com/v1/Server-side pipelines, warehouses, scheduled closeout pullsAPI key header. Super Admin for raw/computed batch
Mobile SDKPhone mediates BLE sync. On-device options in your appiOS via SPM. Android Kotlin Flow BLE
OAuth 2.0 third-party appAn external app sits in the trust boundaryConsent flow. Name the app in the protocol

Confirm current routes and payloads on Developers before you freeze a connector. Endpoint details move. This article states published product facts, not a substitute for the live API reference.

Architecture choice (REST versus SDK versus aggregator) is covered in wearable API for health products. The live path is real-time physiological data streaming. A live stream with no batch export is a coaching product. A trial usually needs the archive.

Configuration before first enrollment

If you cannot set sample rate, duty cycle, and raw export before the first kit ships, you are accepting vendor defaults as your protocol. Prefer a device profile applied once across the cohort.

Name these in the RFP and again in site initiation:

  1. Sample rate (25, 50, or 100 Hz). Pick from the analysis, not from a brochure default.
  2. Raw PPG on or off, and whether that applies to Passive, Rest Mode, or both.
  3. Infrared and red on or off. Green-only is not a bug if you never enabled the other two.
  4. Accelerometer raw on or off.
  5. Cadence for computed outputs (live, 1 min, 5 min, 15 min).
  6. Who holds Super Admin for downloads.

See how to configure a research wearable for the profile version of this list. Do not treat configuration as a week-two support ticket.

Wear-time and missingness reporting

Demand operational views for hours worn, charge gaps, and sync failures. Missingness is a study outcome driver. It should not be a surprise in the CSR.

Ask what the operator actually sees when a device misses a night: last sync time, battery, wear-time proxy, capture profile still matching the protocol. Without that view, support tickets become forensic science.

Wear-time is a protocol object. Write target hours and target nights with a valid window the same way you write visit windows. Then name the owner who watches week one.

PPG signal quality is the optical companion. Wear-time is whether the device was on. Signal quality is whether the optical window is usable while it was on. You need both in the SAP.

Three protocol postures you can score a vendor against

Do not write one RFP for every wearable study. The capture profile changes the battery story, the export story, and the site copy. Walk the vendor through the posture you actually have.

Posture A. Computed overnight features

The analysis plan stops at stored heart rate, rMSSD, respiratory rate, and wear-time. You will not reopen amplitudes.

RFP asks that matter: computed download windows, cadence, Rest Mode behavior, wear-time views, battery under this profile. Raw can stay off. Sample rate can stay at the 50 Hz default unless you have a reason to change it.

Charge copy you can defend sits nearer the published default-settings envelope (5 to 7 days of battery, about 2.5 days on-device storage on V2 comparison figures). Still validate on a canary device.

Posture B. Re-derivable optical record

A reviewer, a model team, or a later amendment may need green / ir / red amplitudes. Morphology or beat re-detection is in scope.

RFP asks that matter: raw on in the modes you need, written sample rate, Super Admin export, 1-7 day raw windows, accel raw if artifact review is planned, infrared and red if the algorithm expects them.

Charge copy moves toward the max-recording envelope (about 2 days battery, about 1.2 hours on-device storage). Nightly charge and frequent sync are the honest instruction until your canary says otherwise. A weekend without sync on this profile is not a small gap.

Posture C. Activity and adherence

Steps, cadence, and hours worn are the endpoints. Optical morphology is out of scope.

RFP asks that matter: activity export, cadence matched to monitors (1 / 5 / 15 min is usually enough), wear-time reporting, whether accel raw is needed or computed steps are enough.

Do not copy a 100 Hz raw-on profile "just in case." Extra channels feel serious. They also move you toward the 2-day / 1.2-hour envelope and a charge SOP participants will not follow.

Those three postures are program illustrations, not care protocols. Score Sensor Bio and every other vendor the same way: walk one protocol through the table, then run one device from profile to file.

For research and product teams

Put the raw signal in your study or product

If the RFP already names waveform export, a locked sample rate, and Super Admin pull windows, we can walk that capture profile before first enrollment.

Evidence questions without overclaiming

When a vendor shares validation materials, score the methods, not the adjective on the slide:

  • What was the reference?
  • Who was in the sample, and under what motion?
  • Was each endpoint validated separately (pulse rate vs interval timing vs other derived metrics)?
  • How were artifact windows and missingness handled?
  • Does the claim match a general wellness product posture, or does it imply diagnosis?

A pulse-rate agreement study is not an interval-timing study. An interval-timing study is not a waveform-morphology study. If the pack collapses those into one number, ask for the split or treat the number as marketing.

Sensor Bio V2 is a general wellness device, not FDA cleared for diagnosis. Trial and research programs should keep product language inside research and program design. Do not treat disease-screening abstracts in a literature pack as a product claim for the current device.

For applied optical context, use the on-site PPG for wearable products overview. Pair it with your own protocol-specific validation plan. Digital biomarkers is the place to write the endpoint so the evidence question has a noun.

Ops realities that kill cohorts

Battery under default settings is not battery under study settings. Sensor Bio V2 comparison figures list 5 to 7 days under default settings and about 2 days under max recording settings, with on-device storage about 2.5 days default versus about 1.2 hours at max recording. Treat those as planning bounds, not promises for every duty cycle. High-rate raw capture needs a charging and sync SOP participants will actually follow.

Planning questionDefault-settings envelopeMax-recording envelope
Battery (published V2 comparison)5 to 7 daysAbout 2 days
On-device storage (published V2 comparison)About 2.5 daysAbout 1.2 hours
Typical trial posture that lands hereComputed metrics, raw off, 50 Hz defaultRaw on, high sample rate, continuous capture
Charge / sync copy you can defendWeekly charge may be plausibleNightly charge and frequent sync

You do not get a published per-rate hour table beyond those two envelopes. Do not invent one. Use the bounds to pick a posture, then validate on a canary device under your duty cycle before you print participant materials.

Also plan for:

  • Kit logistics and replacements. Who ships the spare, who unpairs the failed unit, who confirms the replacement inherited the org profile (rate, raw on/off, cadence).
  • Who holds API keys. Name the role. Rotate on staff change. Super Admin for raw/computed batch is a study-ops object, not an afterthought.
  • How sites escalate a device that will not sync. Last sync time, battery, wear-time, profile match. If the vendor only offers a consumer app, you are the watchlist. Budget that time.
  • Privacy, consent, and BAA. Whether a BAA discussion applies depends on your contracting model. Sensor Bio states willingness to discuss BAAs through the account team. Confirm current compliance status during vendor due diligence. Do not paste a hoped-for BAA into the protocol.
  • Closeout pulls. Computed windows are 1-30 days. Raw windows are 1-7 days. Three concurrent jobs per org. A 90-day raw archive is a sequence of jobs, not one button. Write the closeout calendar against those windows.

Three failure modes show up early and look like "the device did not work":

Charge copy that does not match the profile. Participants were told the default-settings story. The profile is closer to max recording. They charge weekly. Nights go empty. This presents as non-adherence. It is a configuration leak.

Sync that requires a phone nobody carries at night. If the mobile SDK path is in the loop, say so in the participant instruction. If cloud-to-cloud REST is the archive path, say who triggers the pull and how stale a device can get before on-device storage wraps.

Raw promised, raw off at shipment. Defaults keep Sensor Bio raw off in Passive and Rest Mode. Put the on-switch in the initiation checklist. Confirm it on the canary file (ts, green populated, ir / red matching what you enabled) before first enrollment.

How Sensor Bio fits the buyer job

Sensor Bio positions as wearable infrastructure: Capture on V2 hardware, Connect through SDK and API, Build as an org-level device profile, Act as operator views after the signal exists. Sensors on the device are PPG, motion, and skin temperature. On-device computed options include heart rate, HRV (rMSSD), respiratory rate, steps, cadence, beat-to-beat intervals, plus sleep staging, HRV, beat-to-beat, and active minutes on the mobile path.

The buyer-relevant facts are configurable capture, raw PPG when enabled, documented export windows, and a Super Admin pull you can put in the ops plan. Score us the same way you score anyone else.

Use the shorter research wearable checklist in screening calls. Send partners to raw PPG access when they are ready to wire ingestion. When the cohort timeline is already on the calendar, the Get started path is the place to lock that list against a live org, not a slide.

A one-device rehearsal before SIV (or before first shipment, if you have no sites):

  1. Apply the org profile (rate, cadence, sensors, raw on/off).
  2. Wear it through a Passive window and a Rest Mode window.
  3. Pull one computed file (1-30 day window rules) and one raw file if raw is on (1-7 day window rules).
  4. Open the file. Confirm columns. Confirm the interval matches the rate you set.
  5. Leave the phone away long enough to learn storage behavior under this profile.
  6. Write the charge and sync sentence from what you observed, bounded by the published 5 to 7 day / 2-day and 2.5-day / 1.2-hour figures.

If that rehearsal fails, the vendor failed the RFP. If it passes, you have a protocol object you can put in the SAP.

Failure modes in the wearable RFP

Score shopping. A recovery index with a pretty confidence interval is not a channel list. Ask for the upstream signal.

Default-settings battery in the protocol. The brochure number is the default envelope. Your profile may be the other envelope.

Export as a portal screenshot. If the only path is a human clicking through a vendor UI, you do not have automation. You have a bottleneck at closeout.

One sample rate for every study. 25, 50, and 100 Hz are different products in power and storage. Match the rate to the analysis.

Buying the algorithm profile for a coaching-style endpoint. Extra raw channels and 100 Hz feel serious. Serious is the profile that matches the SAP.

No owner for Super Admin. The file exists in a place nobody at the sponsor can pull.

No canary device. First enrollment is a poor time to learn that Rest Mode raw was still off.

Evidence pack used as a product claim. V2 is a general wellness device. Keep language inside research and program design.

FAQ

What data access should trial teams require from a wearable vendor?
Clear rights to the channels you need (raw waveform and/or beat intervals), documented export formats and API contracts, configurable capture before enrollment, and wear-time or missingness reporting you can act on.
Are consumer wearables enough for clinical trials?
Sometimes for coarse adherence or activity endpoints. They often fall short when the protocol needs re-analyzable optical waveforms, org-level sample rate control, or exports that land cleanly in your study systems.
Does Sensor Bio support research and trial-style programs?
Sensor Bio is built as wearable infrastructure for teams that run studies and build health products: configurable sample rates, raw PPG when enabled, REST API and mobile SDKs, and CSV/JSON exports. V2 is a general wellness device, not FDA cleared for diagnosis.
How should we evaluate wearable evidence for a trial?
Ask for the reference method, population, motion conditions, missingness, and whether each endpoint was validated separately. Do not treat a single marketing accuracy number as protocol-ready.
What export windows and roles should a trial plan for?
Plan around documented pull windows, not an unbounded archive dump. Sensor Bio computed downloads cover 1-30 days per request. Raw downloads cover 1-7 days. Concurrent jobs are limited to 3 per organization. Super Admin is required for those batch pulls. Links expire and can be refreshed.
When should a trial enable raw PPG versus computed metrics only?
Enable raw PPG when you may re-derive beats, audit optical quality, or hand a waveform to a reviewer. Computed heart rate, rMSSD, respiratory rate, steps, cadence, and beat-to-beat intervals are enough when the analysis plan stops there. Raw is off by default in Passive and Rest Mode.