Digital biomarkers for program design
Digital biomarkers need a protocol for signal, wear-time, and export, not only a definition. Program design notes for study teams.
Quick answer: A digital biomarker is only as strong as the capture profile, wear-time plan, and export dictionary behind it. Design those with the endpoint before kits ship. The wearable is the instrument; a vendor recovery index alone is not a protocol-defined biomarker your team can re-analyze.
A digital biomarker is a measured endpoint, not a dashboard tile
In research and program design, a digital biomarker is an endpoint you define and defend. The wearable is the capture instrument. If the protocol only stores someone else's recovery index, you do not have a biomarker you can re-open later. You have a screenshot with a timestamp.
Write the analysis question first. Name the feature. Overnight HRV as rMSSD. Respiratory rate from beat intervals. Activity seconds from motion. A custom optical feature you will compute from stored amplitudes. Then ask whether the device will store the upstream signal or intervals you need to re-derive it.
That last question is the whole job. A tile that moves in an app can still be useless at closeout if you cannot map it to a column, a unit, a derivation, and a missingness rule.
Name the feature before you name the device
Teams often start with hardware because hardware is concrete. The better order is:
- What decision or analysis does this feature support?
- What time window does it live in (overnight, daytime, session, week)?
- What must remain on disk if you change the algorithm six months from now?
- Only then: which sensors, sample rate, and export path can produce that record?
If step 3 is "the vendor score," stop. You are buying a dashboard. If step 3 is "beat intervals plus wear-time flags" or "unfiltered green amplitudes with timestamps," you have the start of a biomarker program.
For HRV-style endpoints, read how researchers use continuous HRV after you freeze the interval source. For optical context, use PPG for wearable products. Neither article replaces your statistical analysis plan. They keep the capture question honest.
Decide what you must be able to re-open later
Most teams land in one of three places:
- Score only. A closed index. Fine for coaching UX. Weak as a protocol endpoint because you cannot audit the derivation.
- Computed features plus intervals. Heart rate, rMSSD, respiratory rate, steps, cadence, beat-to-beat intervals. Enough for many wellness and research endpoints if you also store wear-time and quality flags.
- Raw optical amplitudes. Green, and infrared/red when configured. Needed when morphology, custom filters, or later re-derivation are in scope. See raw PPG access for fields and enable steps.
Pick one on purpose. Do not discover at week six that you needed the third and captured the first.
Design the capture profile with the endpoint
Sample rate, duty cycle, and raw vs computed channels are biomarker design choices. They are not afterthoughts for IT.
For Sensor Bio programs the published controls are specific:
- Sample rate is configurable per organization at 25, 50, or 100 Hz. Default is 50 Hz.
- Daytime Passive and overnight Rest Mode use different PPG duty cycles. Raw PPG is disabled by default in both. Turn it on before enrollment if morphology or re-derivation is in scope.
- Sensors you can treat as first-class: PPG, motion, skin temperature.
- Data cadence examples: live, 1 minute, 5 minutes, 15 minutes.
- On-device processing can produce heart rate, HRV (rMSSD), respiratory rate, steps, cadence, and beat-to-beat intervals. Mobile and cloud layers add sleep staging and trend scores. Know which layer owns the endpoint you claim.
If the endpoint only needs beat intervals and computed biometrics, say so and skip the power cost of raw waveform capture. If you may need optical morphology later, enable raw channels (green, and infrared/red when configured) while the cohort is still forming. Profile setup lives in how to configure a research wearable. The shorter vendor screen is the research wearable checklist.
Map each endpoint to a layer
Write the owner next to the feature. A useful row looks like this:
| Endpoint you claim | Upstream you must store | Layer that computes it | Capture implication |
|---|---|---|---|
| Overnight rMSSD | Beat-to-beat intervals, valid-night flag | On-device HRV (rMSSD) | Rest Mode on; raw optional |
| Respiratory rate | Beat intervals or derived series | On-device | Overnight window; wear-time gate |
| Steps / cadence / activity seconds | Motion samples or computed steps | On-device | Motion on; PPG optional |
| Custom pulse morphology | Unfiltered green (and ir / red if used) | Your pipeline | Raw on; lock 25/50/100 Hz |
| Sleep staging or trend scores | Whatever that layer persists | App / cloud | Do not pretend this is on-device HR |
The last row is where programs get sloppy. If the endpoint is a cloud trend score, say that in the protocol. Do not describe it as a sensor measurement.
Three capture profiles you can actually freeze
These are workflow illustrations for general wellness and research operations. They are not diagnostic protocols, and they are not product screening claims.
Overnight interval program. You want rMSSD and respiratory rate from nights people actually slept in the device. Raw can stay off if you trust stored intervals and will not reopen morphology. 50 Hz is the published default and is a reasonable starting point when you are not doing waveform work. Rest Mode must be in the profile. Wear-time is "nights with a valid sleep window," not "days the app opened."
Algorithm and re-derivation program. You will write or swap filters later. Raw must be on before first enrollment. Research workflows often ask for about 100 Hz when waveform detail matters. Green is the default primary channel. Infrared and red appear when those wavelengths are enabled. Budget charging against the max-recording planning bound, not the default wellness bound. Pair optical review with PPG signal quality.
Motion-forward activity program. Steps, cadence, activity seconds. Motion on. PPG only if a heart-related program metric is in the same protocol. Cadence can be 5 or 15 minutes if nobody is coaching live. Raw export is optional. Do not pay for waveforms you will never open.
Same hardware. Three different biomarkers. The profile is the difference.
Cadence is not sample rate
People conflate the two. Sample rate is how often the optical or motion front end is written (25, 50, or 100 Hz). Cadence is how often a package leaves the device path into your workflow (live, 1 min, 5 min, 15 min).
A live cadence on a 50 Hz profile is a product or coaching choice. A 15-minute cadence on a 100 Hz raw profile is still high-rate capture. Delivery is just slower. Write both numbers. Your warehouse job and your statistician care about different ones.
For research and product teams
Put the raw signal in your study or product
If the endpoint is already named, we can walk the capture profile, wear-time plan, and export dictionary before the first kit ships.
Wear-time is part of the biomarker
An endpoint computed on empty nights is missing data, not a soft failure.
If you average rMSSD across a week and three nights have no valid window, you do not have a slightly noisy week. You have a different denominator than the protocol assumed. Treating those nights as zeros, or dropping them silently, changes the endpoint. Put the rule in the data dictionary before the first pull.
Build wear-time into the protocol the same way you build visit windows:
- Target hours worn per day
- Nights with valid sleep windows
- Charge and sync instructions participants will actually follow
- Who watches dropout after week one
- What happens to a record that fails the wear-time gate (exclude, impute, flag, query)
Comfort, strap fit, and charge friction decide whether your n is real. Plan follow-up before the cohort starts. Do not wait for the closeout meeting to discover half the nights are empty.
Battery under study settings is a protocol number
Battery under default wellness settings is not battery under study settings. Sensor Bio V2 comparison figures list 5 to 7 days under default settings and about 2 days under max recording settings. On-device storage is about 2.5 days default versus about 1.2 hours at max recording. Treat those as planning bounds, not promises.
High-rate raw capture needs a tighter charging SOP. If the profile is 100 Hz with raw green (and IR/red when configured), write charge-every-night or charge-every-other-night in the participant instructions, not in a footnote. If the profile is default computed wellness capture, a weekly charge may be enough. The biomarker includes the SOP because the SOP decides whether the series exists.
On-device storage bounds matter for people who travel or skip sync. A max-recording profile that holds about 1.2 hours on device will lose the day if the phone never shows up. Put sync expectations next to the wear-time target.
A week-one dropout watch
Most wear-time loss is front-loaded. Someone cannot get the clasp right. Someone charges the phone and not the band. Someone decides the overnight device is annoying on night three.
Assign an owner for week one:
- Hours worn per day, by participant
- Nights with a valid window
- Last successful sync timestamp
- Charge-gap length
- A human follow-up rule (message, call, replacement kit)
You do not need a fancy adherence product to do this. You need a query against the same exports you already planned, and a person who looks at it twice in the first ten days.
Put the data dictionary in the protocol
Before first pull, write down the columns you expect to land. If your statistician cannot map those columns to the SAP, the biomarker is not ready.
Fields, units, and who computed them
Start with names you can defend:
| Name in your warehouse | Unit | Layer | Typical source on Sensor Bio |
|---|---|---|---|
heart_rate | bpm | On-device | Computed biometric |
hrv_rmssd | ms | On-device | HRV (rMSSD) |
respiratory_rate | breaths / min (your convention) | On-device | Derived from intervals |
steps | count | On-device | Motion |
cadence | steps / min (your convention) | On-device | Motion |
beat_interval | ms (your convention) | On-device | Beat-to-beat |
skin_temp | °C | Device / computed path | Skin temperature |
ts | nanosecond timestamp | Raw download | PPG package |
green / ir / red | unfiltered AU | Raw download | When those channels are enabled |
accel_x / y / z | m/s² | Raw accel (separate enable) | Millisecond timestamps |
Your warehouse names can differ. The point is that each row has a unit, a layer, and a rule for missingness. "Respiratory rate" without a convention for averaging window is not a biomarker. "HRV" without saying rMSSD vs some other feature is not a biomarker.
Export formats, windows, and jobs
Sensor Bio exports CSV and JSON for standard downloads.
- Computed metrics: 1-30 days per request
- Raw metrics: 1-7 days per request
- Concurrent download jobs: 3 per organization
- Links expire and can be refreshed
- Raw and computed downloads require Super Admin
Design the job, not only the file. A 90-day computed series is three to ninety pulls depending on how you chunk it. A 30-day raw series is at least five raw windows. If three jobs are already running, the fourth waits. Put a queue in front of the API. Do not click download by hand on closeout weekend.
Automation path:
- REST at
https://api.sensorbio.com/v1/with an API key header. Partner wiring notes live on Developers and in wearable API for health products. - iOS SDK via SPM and Android Kotlin Flow BLE SDKs when the phone is in the trust boundary. Start from the SDK reference.
- Batch CSV/JSON when you need files before a connector exists.
Confirm current routes and payloads on developers.sensorbio.com before you freeze a connector. Endpoint details move. This article states published product facts, not a substitute for the live API reference.
Roles are part of the dictionary
If Super Admin is one person on vacation, you do not have an export path. Write:
- Who may request raw downloads
- Who may request computed downloads
- Who holds API keys
- Who rotates those keys
- Where files land (bucket, EDC, notebook project)
- Retention after last patient out or last program week
Trial-style RFPs should also read the wearables for clinical trials buyer guide. The data-access language there is the same job as this dictionary, written for contracting.
Validate one loop before first enrollment
A capture profile that has never produced a file in your schema is a rumor.
Run a short path on a staff device:
- Apply the organization profile (sample rate, Passive / Rest Mode, raw on or off, accel on or off).
- Wear it through at least one overnight window and one daytime block.
- Sync.
- Pull computed data through the 1-30 day path.
- If raw is in scope, pull a 1-7 day raw window and confirm
ts,green, and any enabledir/redcolumns. - Land both files in the warehouse table the statistician will actually use.
- Run the wear-time gate on purpose. Confirm an empty night does not become a real rMSSD.
If step 6 fails, you do not have a biomarker. You have a device that blinks. Fix the dictionary and the connector before kits ship.
Ops freeze list to print into the protocol appendix:
- Endpoint name, window, and derivation
- Upstream stored (score / intervals / raw amplitudes)
- Sample rate (25, 50, or 100 Hz)
- Raw PPG state in Passive and in Rest Mode
- Accel raw state
- Sensors on (PPG, motion, skin temperature)
- Delivery cadence (live, 1, 5, or 15 min)
- Wear-time targets and the exclude/flag rule
- Charge and sync SOP matched to the battery planning bound
- Data dictionary table
- Super Admin and key holders
- Week-one dropout owner
When the cohort timeline is already on the calendar, the Get started path is the place to lock that list against a live org, not a slide.
Boundaries that keep programs honest
Sensor Bio V2 is a general wellness device, not FDA cleared for diagnosis. Program copy should stay inside research and infrastructure framing.
Do not treat disease labels, screening abstracts, or clinical-sounding marketing adjectives as product claims for the current device. Do not publish diagnostic thresholds. A cutoff that belongs in a locked analysis plan does not belong on a homepage tile, a partner one-pager, or this kind of public article.
Keep the public sentence boring. The cutoff lives in the SAP. Public copy that says the device "detects" a condition, or that a number below X means a disease state, turns a measurement program into a claim you cannot support. Thresholds, reference ranges, and inclusion cutoffs belong in the protocol. Legal clears exceptions. Engineering does not invent them here.
What you can say in public and in an RFP:
- Which channels you can enable (PPG, motion, skin temperature; raw green / IR / red when configured)
- Which sample rates and export windows exist
- Which layer computes which feature
- That wear-time and missingness are part of the endpoint
- That V2 is a general wellness device
What you should not say:
- Disease-screening performance
- Diagnostic cutoffs
- RPM billing eligibility
- That a dashboard index is the same thing as a re-derivable biomarker
If a literature pack in your files mentions screening research on some other device or method, leave it in the literature pack. Do not promote it as a Sensor Bio product claim.