Wearable API for health products

← Back to The Signal

Wearable API for health products

Wearable API guide for health products: raw PPG, SDK options, and how device APIs differ from fitness data aggregators. For builders and research teams.

Quick answer: A wearable API for health products should expose continuous physiological data your team can re-analyze, not only fitness summaries from many consumer brands. Aggregators shine at breadth. Device platforms shine when you need raw PPG, configurable capture, and one hardware stack. Sensor Bio provides REST for computed metrics. Raw waveforms come from the Mobile SDK raw stream and a per-organization download.

Two kinds of health data API

The phrases wearable API and health data API describe two products that share a JSON shape and almost nothing else. One stitches Fitbit, Oura, Apple, Garmin, and friends. The other is infrastructure under hardware you brand. Both are legitimate. They answer different jobs.

If you only need common wellness metrics from devices people already wear, an aggregator is often the fastest path to a demo. If you are shipping a continuous physiology product, a digital biomarker pipeline, or a study that must reopen the optical record after last patient out, you want a device platform API.

Aggregators (many consumer devices, derived data)

Terra-class aggregators (public Unified API docs reviewed 2026-10-27) connect your app to many wearable and health-app sources through one integration. The wearer picks a provider, authenticates, and the aggregator normalizes activity, sleep, daily totals, body readings, and related payloads into one schema, often delivered by webhook or other destinations as data arrives.

That breadth is the point. You write against one model. You do not maintain thirty OAuth flows.

Limits show up when the product needs sample-rate control, raw PPG waveform, white-label hardware, or operator triggers that fire without a human watching a consumer dashboard. Streaming APIs may expose heart rate, HRV, RR intervals, or ECG when a connected device broadcasts them. Documented Unified and Streaming catalogs we reviewed do not treat raw multi-wavelength PPG as a first-class, hardware-controlled channel the way a device platform does. Availability still depends on what each provider actually exposes.

Device / platform APIs (hardware + signal you control)

A device platform assumes you care about the signal path. You choose or white-label the hardware. You set what is collected before first enrollment. You stream or batch into systems you own. The wearer experience stays inside your product.

Sensor Bio is built as that second shape: Capture, Connect, Build, and Act on one stack. This page is about architecture choice. Endpoint field names live on Developers.

What actually moves on each path

Draw the boxes before you write the connector.

On an aggregator path, the wearer already owns a consumer device. Data lands in that brand's cloud first. Your app receives a normalized event after the wearer consents. You do not set the optical sample rate. You do not decide whether green, red, and infrared amplitudes are stored. You consume what that brand decided to publish, on that brand's latency, in that brand's units.

On a device platform path, the hardware is in your program. Capture settings are an org-level contract. The phone or a gateway syncs to your cloud (or processes beside the handset). Your warehouse is the system of record. If a model team asks for the amplitudes behind last week's recovery number, you either have the file or you do not. That answer should be known before first kit ships, not discovered in month six.

Sensor Bio V2How the data movesBand to phone to cloud, then out. Toggle a path, then hover or tap a box for one line on what moves there.

Then out

Through the API

The Sensor Bio cloud computes sleep, HRV, resting heart rate, SpO2, and breathing rate.

Both paths, in words

  1. Raw waveforms, today. Green, red, and infrared PPG, accelerometer, and skin temperature leave the band on the Mobile SDK raw stream (iOS and Android). Each organization can download those raw waveforms from the web platform. V2 has no ECG and no gyroscope.
  2. Computed metrics. The cloud derives sleep, HRV, resting heart rate, SpO2, and breathing rate. The REST API serves those metrics plus user and organization admin. Your app, warehouse, research platform, or EHR can receive them through the API. There is no built-in EHR integration, and this does not address RPM billing eligibility.

The two paths can coexist in one company. A consumer coaching surface might ingest Apple and Garmin through an aggregator while a research arm runs a locked Sensor Bio profile. Do not pretend they are the same pipeline. They have different identity models, different missingness, and different rights to reopen the record.

What builders should demand from a wearable API

Treat the API surface as a contract, not a slide. Before you bake a vendor into a roadmap, write down the channels, auth model, export windows, and SDK vs REST split you need on day one.

Channels and sampling

Decide which of these you need before first kit ships:

  • Raw PPG waveform when morphology or re-derivation is in scope
  • Beat-to-beat or inter-beat intervals when timing analyses matter
  • Derived heart rate and HRV-style metrics for product UX
  • Motion for artifact context
  • Skin temperature if your endpoints use it
  • Which optical wavelengths must be on

For Sensor Bio V2, raw waveforms are unfiltered green, red, and infrared amplitudes with nanosecond timestamps when those channels are enabled. They come from the Mobile SDK raw stream and a per-organization download. They are not on the REST API. Organizations configure sample rate at 25, 50, or 100 Hz (default 50 Hz). Raw capture is off in Passive and Rest Mode until you turn it on. Write the on-switch into onboarding, not into a late protocol amendment. Deep dive: raw PPG access for partners. Applied optical context: photoplethysmography (PPG).

On V2 hardware, published wavelength centers are green 530 nm, red 655 nm, and infrared 940 nm. Green is the default primary channel. Accelerometer raw (x, y, z in m/s², millisecond timestamps) is a separate enable. If your artifact story depends on motion, turn it on with the optical channels, not as a cleanup ticket after the first dirty night.

White-label and multi-site programs add one more requirement: the same device profile must apply across the cohort. If each phone app can silently change sampling, your warehouse becomes a mixture of protocols. Prefer org-level defaults that study ops or product admins set once, then verify with a canary device before enrollment at scale. Configuration details live in how to configure a research wearable.

Cadence is a separate knob from sample rate. Sensor Bio documents live, 1 minute, 5 minute, and 15 minute cadences. Live supports coaching and in-session features. Longer cadences fit overnight or population programs that do not need a tick on the phone every second. State both the sample rate and the cadence in the same profile review. Teams that lock rate and leave cadence implicit usually discover the mismatch in the warehouse, not in QA.

Auth and roles

Ask who can issue keys, who can download raw windows, and how wearer consent maps to your privacy model. Sensor Bio's documented cloud path uses API key authorization on REST at https://api.sensorbio.com/v1/ for computed metrics and admin, with Super Admin required for computed batch downloads. Raw waveforms are not on that REST path. They come from the Mobile SDK raw stream and a per-organization download. Role design belongs in your ops plan, not in a ticket after launch.

If a third-party app needs wearer consent, confirm OAuth 2.0 or equivalent flows against current docs. Do not hard-code secret endpoints from blog posts into production connectors.

A useful role split for most partners:

RoleTypical rightsKeep it off
Device / app engineerSDK keys, sync debug, non-raw metric readsBulk raw download
Study or program opsWear-time views, device status, computed windowsUnscoped warehouse dumps
Super AdminComputed batch jobsDay-to-day app deploys
Wearer-facing appOnly the data that consent coversOrg-wide export

If the same service account can enroll users, pull raw nights, and push config, a leaked key is a program incident. Split the keys even when the team is small.

Export windows and formats

Builders usually need:

  • CSV and JSON at minimum
  • Clear pull windows and concurrency limits
  • Retention and re-download rules after a study or program ends
  • A path that does not expire into a proprietary viewer

Sensor Bio documents computed downloads over 1-30 day windows, with concurrent download jobs limited to 3 per organization in current docs. Raw waveforms are not those REST jobs. They come from the Mobile SDK raw stream and a per-organization download. Links expire and can be refreshed. Plan job orchestration accordingly.

That limit is an architecture input, not a footnote. A 90-day backfill for 200 subjects is not one job. Chunk by subject-week or by calendar window, persist job id and window in your warehouse, and treat an expired link as a retry, not a missing night. Idempotent loads keyed on org + subject + window + job id save you from double-counting when a refresh lands twice.

On-device computed outputs (when you process beside the handset) include heart rate, HRV as rMSSD, respiratory rate, steps, cadence, and beat-to-beat intervals. Sleep staging, HRV, beat-to-beat, and active minutes are documented on-device options. Cloud computed downloads cover the longer program windows. Decide which layer is canonical for each metric before two pipelines disagree in a partner review.

Mobile SDK vs REST

PathWhen it fits
Mobile SDKPhone mediates BLE sync; you want on-device or near-device processing inside your app
REST / cloud APIServer-side pipelines, warehouses, EDC-adjacent jobs, multi-site ops
Batch exportStudy ops and partner validation before a full connector ships

Sensor Bio documents native BLE SDKs for iOS (SPM) and Android (Kotlin Flow), plus on-device algorithm options for sleep staging, HRV, beat-to-beat intervals, and active minutes when processing beside the handset matters. Pick SDK vs pure cloud based on trust boundary, not preference.

Live streaming vs batch cadence is a product choice. Live streams support coaching and real-time features. Batch cadence supports studies and lower-power programs. Your API should make the tradeoff explicit. See also real-time physiological data streaming.

A practical rule: if the phone is inside your trust boundary and the wearer is looking at a live session, start with the SDK. If a statistician, EDC, or warehouse job needs nights after the fact, start with REST and batch. Many products need both. Design the identity join first so a session on the phone and a nightly file in the warehouse describe the same wearer.

Fair compare snapshot (dated)

Facts below reflect public documentation reviewed 2026-10-27 (America/Chicago). Vendor surfaces move. Re-check before you freeze a connector. This table is architectural, not a ranking.

DimensionTerra-class aggregatorsGarmin Health APISensor Bio (device platform)
Primary jobOne schema across many consumer sourcesEnterprise access to Garmin Connect health summariesHardware + SDK/API under your product
Typical payloadActivity, sleep, daily, body, nutrition-style modelsJSON summaries (steps, HR, sleep, stress, pulse ox, Body Battery, and related metrics)Computed metrics on the API. Raw PPG and motion on the SDK stream and the per-organization download
Raw optical waveformNot a first-class, org-controlled PPG channel in Unified docs reviewedNot positioned as multi-wavelength raw PPG; enhanced beat-to-beat interval noted for enterprise accessGreen, red, and infrared PPG on the SDK raw stream and the per-organization download
Hardware controlWearer-owned devicesGarmin devices synced to Garmin ConnectSensor Bio V2 stack you configure
Access modelWidget + provider OAuth; event deliveryApproval / evaluation environment; push or ping-pullPartner keys; REST + iOS/Android SDKs + batch export
Best whenBreadth across brands is the productYour users already live in GarminYou need waveform access and one capture profile

Sources: Terra Unified API and Streaming data-types docs; Garmin Connect Developer Program Health API feature pages; Sensor Bio partner docs mirrored on The Signal (raw PPG access, configure a research wearable).

Fairness rules for this page: no trash talk, no invented competitor sample rates, no claim that an aggregator can never deliver intervals when a device broadcasts them. The fork is control of capture and re-analysis rights.

If you are talking to an aggregator because you need waveform-level control, say that in the vendor call. Coverage and price questions stay with aggregators. Capture control and re-analysis rights move you to a device platform. Sensor Bio sits in the second category.

What a physiological wearable SDK actually is

People who say "biometric SDK" in a health-product meeting often mix two markets. Identity vendors mean fingerprints, face match, and access control. Physiology teams mean heart rate, HRV, intervals, motion, and optionally raw PPG into an app they own. If your RFP still says biometric SDK, write the physiological channels in the same sentence so the shortlist does not fill with access-control vendors.

What you actually get from Sensor Bio is the physiology path: iOS and Android sync, cloud REST for warehouses and study systems, and org-level capture config that survives beyond a single phone install. A wearable SDK that only reprints the same derived scores as a consumer app is a client library. Ask whether the SDK can stream or store the channels your algorithms need, and whether the org-level profile still wins after an app update.

Architecture that survives first enrollment

The stack language is Capture, Connect, Build, Act. Translate that into systems you can draw on a whiteboard.

Capture. Org-level sample rate, raw on or off, wavelengths, motion enable, and cadence. This is the contract the device will honor for every wearer on the profile. Change it after enrollment and you have two studies in one warehouse.

Connect. BLE through the mobile SDK, or a later cloud pull through REST and batch. The phone is a sync peer, not the archive, unless you deliberately make it one. Decide where a night lives if the handset is offline for three days.

Build. Your product schema, warehouse tables, and any on-device algorithms you choose to run. Version the schema. Store the capture profile id next to every row.

Act. Coaching UI, operator alerts, study dashboards, or a statistician's extract. Act is allowed to be lossy. Capture is not.

For research and product teams

Put the raw signal in your study or product

If you already know you need waveform export and a locked sample rate, we can walk the capture profile before first enrollment.

Trust boundary: phone, cloud, warehouse

Three common shapes:

  1. Phone-centric product. The iOS or Android app is the product. The SDK handles BLE, optional on-device HRV or sleep staging, and a sync up to your backend for account features. Fits coaching and consumer-adjacent wellness. Fails when a site coordinator needs last week's raw files and the only copy is on a locked personal phone.

  2. Cloud-centric program. Devices sync through a supported path, then REST and batch jobs land in a warehouse you own. Fits multi-site studies and partner validation. Fails when you promised a live in-session feature and the only path you built is a nightly job.

  3. Split trust. Phone for the live session, cloud for the archive. Most products that start phone-only or cloud-only end up here once a coach wants a live session and a statistician wants last month's files. It only works if wearer id, device id, and your subject id join cleanly, and if the capture profile on the phone matches the profile the warehouse thinks it received.

Hardware selection sits next to this choice. If you are still deciding whether a white-label stack or a wearer-owned device is the right kit, read how to choose a wearable for research before you freeze the connector.

Identity join

A wearable API that cannot name the wearer, the device, and your subject in one row will leak time in support. Persist at least:

  • Your user or subject id
  • Partner / platform wearer id
  • Device identifier
  • Organization id
  • Capture profile version (sample rate, raw flags, cadence)
  • Firmware or device generation
  • Export job id when the row came from batch

When a night is missing, you want to know whether the device was unworn, the phone failed to sync, the job expired, or the profile never enabled the channel. Those are four different tickets.

Sync, jobs, and partial nights

Wearable APIs fail in the gaps. Design for:

  • Late sync. The wearer charged on Sunday and the phone uploaded Monday. Your daily job ran Sunday night and wrote "missing." The Monday job must update Sunday, not append a second Sunday.
  • Partial nights. Four hours worn, then the device came off. A computed nightly rMSSD without a wear-time field will look like physiology.
  • Job expiry. Batch links expire. Refresh is normal. Your loader should treat a new URL for the same window as the same payload.
  • Concurrency. Three computed download jobs at a time means a naive fan-out across sites will queue. A small worker pool with a per-org semaphore is enough. A burst of one job per subject is not.

Battery and storage are part of the same design. Published V2 comparison figures list 5 to 7 days of battery under default settings versus about 2 days under max recording, and about 2.5 days of on-device storage under default versus about 1.2 hours under max recording. Treat those as planning bounds, not promises. A max-rate raw profile that the wearer cannot charge will produce beautiful files for two days and silence after that.

Open mHealth and warehouse patterns

Many builder teams ask how a wearable API lands in a warehouse or research store. Open mHealth's public schema library and data-point model (docs reviewed 2026-10-27) describe JSON data points with a header (identity, timestamps, schema id, provenance) and a body that conforms to a measure schema. That pattern is useful even when you do not adopt Open mHealth wholesale:

  1. Keep provenance: device, org, capture profile, and export job id.
  2. Separate raw amplitudes from derived metrics.
  3. Version the schema your product promises.
  4. Make deletion and retention hooks explicit.

If you map into Open mHealth-style points, IEEE 1752-adjacent schemas, or an internal warehouse table, ask one product question: can a new teammate reconstruct what was captured six months later?

A concrete landing pattern that holds up:

StoreGrainProvenance you keep
raw_ppgSample (ts, green, ir, red)device, profile, job id, subject
intervalsBeat or pulse intervaldetector version, quality flags
derived_metricsWindow (night, 5 min, session)metric name, window rule, wear-time
header / auditPoint or fileschema id, export time, consent scope

Do not collapse those four into one "wearable_json" blob. The blob is fine as a landing zone. The product contract is the typed tables and the header that says which profile produced them.

Deletion is easier when raw and derived are separate. A wearer who withdraws consent may require amplitude files to go while aggregated, de-identified program metrics stay under a different policy. If everything is one object store prefix, legal and engineering will invent a process under deadline.

Raw PPG as the contract for model and research teams

Aggregated scores are convenient. They are also someone else's interpretation layer.

Model teams, digital biomarker programs, and research ops that need to reopen the optical record after the first pass should treat raw PPG as a contract item. You store amplitudes. You re-derive later. You review artifact instead of guessing why a recovery index moved.

Sensor Bio positions raw access as opt-in infrastructure: enable channels, pick sample rate, validate one short capture end to end (device → SDK raw stream or per-organization download → your schema), then enroll. Higher rates and more raw channels cost power and storage. Budget charging time in the product SOP.

How much raw data is that? The rows scale with sampling rate and duty cycle. This chart uses only the published V2 capture settings (25, 50 or 100 Hz; 45 seconds every 5 minutes by default, or continuous), so you can size storage and sync before the first enrollment.

Raw PPG volumeHow many raw PPG rows one band produces in a dayEach raw row holds a timestamp, the green channel, and infrared or red if enabled. Pick a sampling rate and a duty cycle to see the daily volume per worn band.
Sampling rate
Duty cycle
Rows per day648,000Signal captured3.6 h a dayDuty cycle45 seconds every 5 minutes
  • Default duty cycle, 25 Hz324,000 rows
  • Default duty cycle, 50 Hz648,000 rows
  • Default duty cycle, 100 Hz1,296,000 rows
  • Continuous, 25 Hz2,160,000 rows
  • Continuous, 50 Hz4,320,000 rows
  • Continuous, 100 Hz8,640,000 rows

Arithmetic from the published V2 capture settings (25, 50 or 100 Hz; default 45 seconds every 5 minutes, or continuous), not measured wearer data. Real volume also depends on wear time and the configuration Sensor Bio sets for your organization. Raw capture is off by default and enabled per organization.

If your question is really about study ops rather than product embedding, start with wearables for clinical trials and digital biomarkers.

A short worked check before you promise a model feature:

  1. Enable raw on a canary org profile (50 Hz is the default; use 100 Hz only if the analysis plan needs it).
  2. Wear one device through a known motion period and a still period.
  3. Pull the raw window from the Mobile SDK raw stream or the per-organization download. REST serves computed metrics, not raw waveforms, so skip it for this check.
  4. Confirm ts, green, and any enabled ir / red land in your schema with the profile id attached.
  5. Recompute a trivial heart-rate estimate on the still segment so you know the file is not empty AU noise.
  6. Only then talk about enrollment counts.

If step 4 fails, you do not have raw access in the sense your model team means it. You have a docs page.

Privacy, retention, and operator trust

API design is also privacy design. Decide early who can pull identifiable exports, how long raw windows live in your warehouse, and what happens when a wearer withdraws consent. Those rules belong next to the connector code, not in a slide after launch.

Operators need a boring status view: last sync time, battery, wear-time proxy, and whether the capture profile still matches the protocol. Without that, support tickets become forensic science. Pair the wearable API with internal dashboards that answer "is this subject still producing usable nights?" before you promise any model feature.

Sensor Bio ships as general wellness hardware with configurable capture. Your compliance team still owns the program-level policies for storage, deletion, and what language appears in product UI. Keep those policies written before the first cohort sync.

Third-party apps that sit outside your first-party product should use wearer consent (OAuth 2.0 or the current equivalent in the docs), not a borrowed Super Admin key. The key is for your org's jobs. The consent flow is for someone else's app reading a wearer who said yes.

Common failure modes when the API choice is wrong

Teams rarely fail because JSON parsing is hard. They fail because the contract does not match the product job.

Breadth without re-analysis rights. An aggregator can light up a dashboard in a week. Six months later a model team asks for the optical amplitudes behind a sleep score and discovers the provider never exposed them. If re-derivation is on your roadmap, put waveform rights in the RFP on day one.

Hardware you do not control. Wearer-owned devices change firmware, sample behavior, and consent flows without your release train. That is acceptable for lifestyle coaching. It is expensive for a study archive or a white-label product promise.

SDK theater. A mobile SDK that only surfaces the same derived scores as the consumer app is not infrastructure. Ask whether the SDK can stream or store the channels your algorithms need, and whether org-level config survives app updates.

Hidden power budgets. Max-rate raw capture that drains a battery in about two days will destroy adherence unless charging is designed into the program. Sensor Bio publishes the default versus max-recording contrast for that reason. Put charging SOP next to the API SOP. The 1.2-hour max-recording storage bound is the same class of surprise: the device fills, recording stops, and the warehouse looks like the wearer gave up.

Docs drift. Blog posts go stale. Freeze connectors against the live reference on developers.sensorbio.com, and re-verify before each major release.

Mixed profiles across sites. Site A left raw off. Site B turned on 100 Hz. The combined extract is not one study. Pin the profile in the protocol and reject devices that report a different hash.

Identity collisions. Two wearers share a loaner phone, or a device is reassigned without a new binding. Nightly files attach to the wrong subject. Bind device to subject in your system of record the same day the kit is handed out, and unbind on return.

Consent and key mismatch. A partner app uses an org API key to read wearers who never consented to that app. That is a privacy incident waiting on the first audit, not a shortcut.

Webhook versus batch races. An event arrives before the batch file, or the batch file arrives twice. If your loader is not idempotent on window plus job id, dashboards double-count.

Retention after contract end. You can pull nights today. Confirm you can pull them after the study closes, and what format you keep if the vendor link dies. Export into your warehouse on a schedule you own.

Operator blindness. The API works. Nobody can see that site 3 stopped syncing on Thursday. Ship the status view with the connector.

Cadence mismatch. Product promised a live session. Engineering built a 15-minute batch. Both are valid Sensor Bio cadences. They are not interchangeable in a demo to a coach.

Builder checklist before a demo

Use this as a pre-call sheet with vendors (including us). Fill it for the product you are actually shipping, not the one in the pitch.

  1. Which channels are contractually available: raw PPG, intervals, HR/HRV, motion, temperature?
  2. Who sets sample rate and duty cycle: wearer app, org admin, or immutable firmware default?
  3. What are the export windows, concurrency limits, and retention after contract end?
  4. Is white-label hardware in scope, or are you integrating devices people already own?
  5. Which identity model maps wearer, device, and your subject id?
  6. What does a failed sync look like for operators?
  7. Which claims language is allowed in your market for a general wellness device?
  8. Which path is in the trust boundary: mobile SDK, REST, batch, or all three?
  9. What happens to in-progress capture if the phone is offline for 48 hours?
  10. Who may enable or disable raw after enrollment, and is that change audited?
  11. How are expired download links refreshed, and is the reload idempotent?
  12. Where does deletion run when a wearer withdraws: vendor side, your warehouse, or both?

If answers 1-3 are fuzzy, you do not have an API strategy yet. You have a slide.

Two filled examples, abbreviated:

Coaching app, wearer-owned phone in trust boundary. Channels: computed HR, rMSSD, sleep, optional intervals. Sample rate: org default 50 Hz, raw off. Export: SDK sync plus computed 1-30 day jobs for the data science backup. Hardware: white-label or program-issued, not "any watch the user owns." Operator view: last sync and battery in the coach console. Claims: general wellness, no diagnostic language.

Multi-site digital biomarker program. Channels: raw PPG on for a waveform audit subset, intervals and nightly rMSSD for the full cohort, motion on. Sample rate: 50 Hz cohort default, 100 Hz on the audit subset only if the analysis plan needs it. Export: computed metrics through REST. Raw waveforms from the SDK raw stream or the per-organization download. Identity: subject id from EDC joined to device id at kit handoff. Operator view: wear-time and profile hash per site. Claims: research and program physiology, not diagnosis. Hardware and endpoint framing: digital biomarkers and wearables for clinical trials.

If those two products share one connector and one profile, one of them is lying.

Getting started path (docs + Get Started)

A practical path for product and research engineering:

  1. Decide aggregator vs device platform with this page and your channel checklist.
  2. Lock the capture profile (sample rate, raw on/off, wavelengths, cadence) before first enrollment.
  3. Issue SDK or API keys from the admin path your contract provides.
  4. Validate one short capture into your schema.
  5. Wire streams or batch jobs into the systems of record you already run.
  6. Add operator rules only after the signal path is trusted.
  7. Document the warehouse schema and deletion hooks your compliance team expects.

Technical reference stays on the Developers hub. When you are ready to scope a program, use Get started.

FAQ

What is a wearable API?
A wearable API lets your product read continuous physiological data from devices (and often write capture config) so your stack is the system of record, instead of forcing wearers into a separate consumer app.
How does a wearable API differ from a fitness data aggregator?
Aggregators stitch derived summaries from many consumer brands the wearer already owns. Device or platform APIs sit under hardware you brand and configure, with optional raw waveform access and one capture stack.
Does Sensor Bio provide raw PPG through its API?
Not through REST. V2 raw waveforms come from the Mobile SDK raw stream on iOS and Android, and from a per-organization download on the web platform. Sample rate is configurable at 25, 50, or 100 Hz (default 50 Hz). Confirm current field names on developers.sensorbio.com.
How does Sensor Bio compare to the Garmin Health API?
Garmin Health API (as of public developer docs reviewed 2026-10-27) delivers JSON summaries from data synced into Garmin Connect, with enterprise approval and optional enhanced beat-to-beat interval access. Sensor Bio is a device platform API: one hardware stack, org-level capture config, and raw waveforms from the SDK raw stream and a per-organization download. Pick Garmin when your users already wear Garmin; pick a device platform when you need waveform control under your brand.
Is there a mobile SDK as well as REST?
Yes. Sensor Bio documents iOS (SPM) and Android (Kotlin Flow) BLE SDKs for device-adjacent sync, plus cloud REST for server-side workflows. Choose based on whether the phone is inside your trust boundary.
Who should use an aggregator vs a device platform API?
Use an aggregator when breadth across consumer devices is the product. Use a device platform when you need raw PPG, locked sample rates, white-label hardware, or operator tooling on one stack you control.